Skip to main content Skip to search Skip to main navigation
Menu

Capillary columns GC BP10

Description
14 % Cyanopropylphenyl Polysiloxane. For analysis of organochlorine pesticides. Suitable replacement for: DB-1701, Rtx-1701, SPB-7, HP-1701, CP-Sil 19CB, 007-1701, PE-1701, SP-1701.

  • Low bleed

  • Highly inert

  • Able to be solvent rinsed

Properties
Film thickness: 1.00 µm
Int. Ø: 0.32 mm
Length: 30 m
Manufacturer Article Number: 054270
Max. temperature programme: 280 °C
Temperature max isotherm: 260 °C
Skip product gallery

Similar products

OPTIMA® 5 capillary columns for GC
5% phenyl - 95% dimethylpolysiloxane USP G27, G36 nonpaolar standard phase with large range of application similar phases: Permabond® SE-52 , SE-54, SE-52, DB-5, HP-5, SPB-5, CP-Sil 8, Rtx-5, 007-5, BP5, MDN-5, AT-5, ZB-5 for columns with 0.1 to 0.32mm ID and films
From CHF 436.80*

OPTIMA® 5 MS Accent capillary columns for GC
silarylene phaseWith polarity similar to a 5 % diphenyl -95 % dimethylpolysiloxane phase.USP G27, G36Lowest column bleed, nonpolar phase, ideal for ion trap and quadrupol MS detectors solvent rinsing for removal of impurities applicableApplication areas: all-round phase for environmental analyses, trace analyses, EPA methods, pesticides, PCB, food and drug analysessimilar phases: DB-5 MS, HP-5 MS, Ultra-2, Equity-5, CP-Sil 8 CB low bleed/MS, Rtx-5SIL-MS, Rtx-5 MS, 007-5 MS, BPX5, MDN-5S, AT-5 MS, VF-5 MSMax. temperature for isothermal operation: 340 °C,Max. temperature for short isotherms in a temperature programme: 360 °Cfor cloumns with film thicknesses > 5.5 µm the max. temperatures are 320 and 340 °CEach column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules. Column ends are melted or closed with septa, and thus protected from atmospheric oxygen.Additionally, we supply the corresponding test mixture with each column.
From CHF 1,007.20*

Optima® 17 capillary columns for GC
phenylmethylpolysiloxane (50 % phenyl)medium polar phasepreferred applications: steroids, pesticides, drug analysesUSP G3similar phases: OV-17, DB-17, HP50+, HP17, SPB-50, SP-2250, Rtx-50, CP-Sil 24 CB, 007-17, ZB50 max. temperature for isothermal operation: 320°C, max. temperature for short isotherms in a temperature programme: 340°C, for 0.53mm ID columns the max. temperatures are 300 and 320°C, resp.In addition to this standard programme we will be happy to supply columns custom-made to your specifications.
From CHF 436.80*

OPTIMA® 5 MS capillary columns for GC
5% diphenyl - 95% dimethylpolysiloxanenonpolar phase with low bleeding, deal for GC/MS and ECD applications and general analyses at trace level perfect inertness for basic compounds.Similar phases: DB-5 MS, HP-5 MS, Ultra-2, Equity-5, CP-Sil 8 CB low bleed/MS, Rtx-5SIL-MS, Rtx-5 MS, 007-5 MS, BPX5, MDN-5S, AT-5 MS, VF-5 MS.max. temperature for isothermal operation: 340°C, max. temperature for short isotherms in a temperature programme: 360 °CCustom-made columns to your specifications available on request.Each column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules. Column ends are melted or closed with septa, and thus protected from atmospheric oxygen.Additionally, we supply the corresponding test mixture with each column.
From CHF 898.60*

Optima® 1701 capillary columns for GC
14 % Cyanopropyl-phenyl - 86 % Dimethylpolysiloxane USP G46medium polar phasespecial selectivity due to high cyanopropyl contentreference column for structure identification, e.g. in combination with Optima 5film thickness 1 µm for solvent analysessimilar phases: OV-1701, DB-1701, CP?Sil 19 CB, HP-1701, Rtx-1701, SPB-1701, 007-1701, BP10, ZB-1701max. temperature for isothermal operation: 280°C, max. temperature for short isotherms in a temperature programme: 300°CCustom-made columns to your specifications on request.Each column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules.Column ends are melted or closed with septa, and thus protected from Additionally, we supply the corresponding test mixture with each column.
From CHF 782.10*

OPTIMA® 225 capillary columns for GC
50% cyanopropylmethyl - 50% phenylmethylpolysiloxaneUSP G7 / G19middle polar phaserecommended for fatty acid analysessimilar phases: DB-225, HP-225, OV-225, Rtx-225, CP-Sil 43, 007-225, BP225max. temperature for isothermal operation: 260°C, max. temperature for short isotherms in a temperature programme: 280°CCustom-made columns to your specifications available on request.Each column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules.Column ends are melted or closed with septa. Additionally, we supply the corresponding test mixture with each column.
From CHF 436.80*

Optima® 624 capillary columns for GC
6% cyanopropyl-phenyl - 94% dimethylpolysiloxaneUSP G43medium polar phaserecommended for environmental analysessimilar phases: HP-624, HP-VOC, DB-624, DB-VRX, SPB-624, CP-624, Rtx-624, Rtx-Volatiles, 007-624, BP624, VOCOLmax. temperature for isothermal operation: 280°C, max. temperature for short isotherms in a temperature programme: 300°CCustom-made columns to your specifications avaialble on request.Each column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules.Column ends are melted or closed with septa. Additionally, we supply the corresponding test mixture with each column.
From CHF 782.10*

Optima® 624 LB capillary columns for GC
6% cyanopropyl-phenyl - 94% dimethylpolysiloxaneUSP G 43medium polar phaselow bleed columns for halogenated hydrocarbons, volatiles, aromatic compounds, solvents etc.similar phases: HP-624, HP-VOC, DB-624, DB-VRX, SPB-624, CP-624, Rtx-624, Rtx-Volatiles, 007-624, BP624, VOCOLmax. temperature for isothermal operation: 280°C, max. temperature for short isotherms in a temperature programme: 300°CCustom-made columns to your specifications available on request.Each column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules.Column ends are melted or closed with septa. Additionally, we supply the corresponding test mixture with each column.
From CHF 962.00*

Capillary columns HT8 / Fast PCB
8 % Phenyl Polycarborane-siloxane. Ultra high temperature columns for polychlorinated biphenyl compounds (PCB), nitro-substituted aromatics, polynuclear aromatic hydrocarbons, pesticides and herbicides.
From CHF 721.00*

Capillary columns HT5
5% Phenyl Polycarborane siloxane. Ultra-high temperature columns for simulated distillation applications, general hydrocarbon profiles, pesticides, herbicides and for GCMS applications.
From CHF 650.00*