Capillary columns GC BPX35 | Int. diam. mm: 0.25

35 % Phenyl Polysilphenylene-siloxane. Suitable Replacement for: DB-35, DB-35ms, Rtx-35, HP-35, HP-35MS, SPB-35, MDN-35.

  • Very low bleed

  • Inert

  • Mid polarity column

  • Equivalent to USP phase G42

  • High temperature

  • Able to be solvent rinsed

Film thickness µm: 0.25
Int. diam. mm: 0.25
Length m: 30
Temp. range °C: 10 ... 330 / 360

Similar products

OPTIMA® 5 MS capillary columns for GC
5% diphenyl - 95% dimethylpolysiloxanenonpolar phase with low bleeding, deal for GC/MS and ECD applications and general analyses at trace level perfect inertness for basic compounds.Similar phases: DB-5 MS, HP-5 MS, Ultra-2, Equity-5, CP-Sil 8 CB low bleed/MS, Rtx-5SIL-MS, Rtx-5 MS, 007-5 MS, BPX5, MDN-5S, AT-5 MS, VF-5 MS.max. temperature for isothermal operation: 340°C, max. temperature for short isotherms in a temperature programme: 360 °CCustom-made columns to your specifications available on request.Each column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules. Column ends are melted or closed with septa, and thus protected from atmospheric oxygen.Additionally, we supply the corresponding test mixture with each column.
From CHF 898.60*

Optima® FFAP capillary columns for GC
polyethylene glycol 2-nitroterephthalateclose equivalent USP G25 / G35polar phaserecommended for FAME, free carboxylic acidssimilar phases: Permabond FFAP , DB-FFAP, HP-FFAP, CP-Sil 58 CB, 007-FFAP, CP-FFAP CB, Nukolfor columns with 0.10 to 0.32mm ID the max. temperature for isothermal operation is 250°C, the max. temperature for short isotherms in a temperature programme is 260°C for 0.53mm ID columns the max. temperatures are 220 and 240°C, resp.Custom-made columns to your specifications on request.Each column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules. Column ends are melted or closed with septa, and thus protected from atmospheric oxygen.Additionally, we supply the corresponding test mixture with each column.
From CHF 436.80*

Capillary columns HT5
5% Phenyl Polycarborane siloxane. Ultra-high temperature columns for simulated distillation applications, general hydrocarbon profiles, pesticides, herbicides and for GCMS applications.
From CHF 624.70*

GC Capillary columns HYDRODEX β-6TBDM
cyclodextrin derivatives with high melting point:for GC-enantiomer separation diluted with polysiloxanesHeptakis-(2,3-di-O-methyl-6-O-t-butyldimethyl-silyl)-β-cyclodextrin. Phase diluted with optimised polysiloxane recommended for γ-lactones, cyclopentanones, terpenes, esters, tartrates.Max. temperature for isothermal operation: 230°CMax. temperature for short isotherms in a temperature programme: 250°C
From CHF 1,976.00*

GC Capillary columns HYDRODEX β-TBDAC
cyclodextrin derivatives with high melting point:for GC-enantiomer separation diluted with polysiloxanesHeptakis-(2,3-di-O-acetyl-6-O-t-butyldimethyl-silyl)-β-cyclodextrin. Phase diluted with optimised polysiloxane recommended for alcohols, esters, ketones, aldehydes, δ-lactones.Max. temperature for isothermal operation: 220°CMax. temperature for short isotherms in a temperature programme: 240°C
From CHF 1,814.80*

OPTIMA® 1 MS Accent ultra-low bleed capillary columns for GC
100 % dimethylpolysiloxanenonpolar phase with ultra-low bleeding, ideal for ion trap and quadrupol MS detectors increased sensitivity due to an unmatched low background level perfect inertness for basic compoundssolvent rinsing for removal of impurities applicableapplication areas: all-round phase for environmental analyses, trace analyses, EPA methods, pesticides, PCB, food and drug analysessimilar phases: Ultra-1, DB-1 MS, HP-1 MS, Rtx-1 MS, Equity™1, AT-1 MS, VF-1 MS, CP-Sil 5 CB MSmax. temperature for isothermal operation 340 °C, max. temperature for short isotherms in a temperature programme 360 °CEach column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules. Column ends are melted or closed with septa, and thus protected from atmospheric oxygen.Additionally, we supply the corresponding test mixture with each column.
From CHF 956.80*

OPTIMA® 5 MS Accent capillary columns for GC
silarylene phaseWith polarity similar to a 5 % diphenyl -95 % dimethylpolysiloxane phase.USP G27, G36Lowest column bleed, nonpolar phase, ideal for ion trap and quadrupol MS detectors solvent rinsing for removal of impurities applicableApplication areas: all-round phase for environmental analyses, trace analyses, EPA methods, pesticides, PCB, food and drug analysessimilar phases: DB-5 MS, HP-5 MS, Ultra-2, Equity-5, CP-Sil 8 CB low bleed/MS, Rtx-5SIL-MS, Rtx-5 MS, 007-5 MS, BPX5, MDN-5S, AT-5 MS, VF-5 MSMax. temperature for isothermal operation: 340 °C,Max. temperature for short isotherms in a temperature programme: 360 °Cfor cloumns with film thicknesses > 5.5 µm the max. temperatures are 320 and 340 °CEach column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules. Column ends are melted or closed with septa, and thus protected from atmospheric oxygen.Additionally, we supply the corresponding test mixture with each column.
From CHF 956.80*

Optima® 17 capillary columns for GC
phenylmethylpolysiloxane (50 % phenyl)medium polar phasepreferred applications: steroids, pesticides, drug analysesUSP G3similar phases: OV-17, DB-17, HP50+, HP17, SPB-50, SP-2250, Rtx-50, CP-Sil 24 CB, 007-17, ZB50 max. temperature for isothermal operation: 320°C, max. temperature for short isotherms in a temperature programme: 340°C, for 0.53mm ID columns the max. temperatures are 300 and 320°C, resp.In addition to this standard programme we will be happy to supply columns custom-made to your specifications.
From CHF 436.80*

Optima® 1701 capillary columns for GC
14 % Cyanopropyl-phenyl - 86 % Dimethylpolysiloxane USP G46medium polar phasespecial selectivity due to high cyanopropyl contentreference column for structure identification, e.g. in combination with Optima 5film thickness 1 µm for solvent analysessimilar phases: OV-1701, DB-1701, CP?Sil 19 CB, HP-1701, Rtx-1701, SPB-1701, 007-1701, BP10, ZB-1701max. temperature for isothermal operation: 300°C, max. temperature for short isotherms in a temperature programme: 320°Cfor 0.53mm ID columns the max. temperatures are 280 and 300°C, resp.Custom-made columns to your specifications on request.Each column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules.Column ends are melted or closed with septa, and thus protected from Additionally, we supply the corresponding test mixture with each column.
From CHF 782.10*

OPTIMA® 225 capillary columns for GC
50% cyanopropylmethyl - 50% phenylmethylpolysiloxaneUSP G7 / G19middle polar phaserecommended for fatty acid analysessimilar phases: DB-225, HP-225, OV-225, Rtx-225, CP-Sil 43, 007-225, BP225max. temperature for isothermal operation: 260°C, max. temperature for short isotherms in a temperature programme: 280°CCustom-made columns to your specifications available on request.Each column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules.Column ends are melted or closed with septa. Additionally, we supply the corresponding test mixture with each column.
From CHF 436.80*