Capillary columns SolGel-Wax | Int. diam. mm: 0.25

Polyethylene Glycol (PEG) in a SolGel matrix. Suitable replacement for: DB-Wax, Rtx- Wax, Stabilwax, HP20M, HP-Wax, HP-INNOWax, Supelcowax-10, AT-Wax, Nukol, CP, Wax 52CB, VB-WAX, ZB-WAX.
  • Robust high-temperature column.
  • Polar phase
  • Low bleed and inert

Dual Use: 0
Film thickness µm: 0.25
Int. diam. mm: 0.25
Length m: 60
Manufacturer Article Number: 054791
Temp. range °C: 30 … 260 / 280

Similar products

GC Capillary columns HYDRODEX β-6TBDM
cyclodextrin derivatives with high melting point:for GC-enantiomer separation diluted with polysiloxanesHeptakis-(2,3-di-O-methyl-6-O-t-butyldimethyl-silyl)-β-cyclodextrin. Phase diluted with optimised polysiloxane recommended for γ-lactones, cyclopentanones, terpenes, esters, tartrates.Max. temperature for isothermal operation: 230°CMax. temperature for short isotherms in a temperature programme: 250°C
From CHF 1,976.00*

Capillary columns HT8 / Fast PCB
8 % Phenyl Polycarborane-siloxane. Ultra high temperature columns for polychlorinated biphenyl compounds (PCB), nitro-substituted aromatics, polynuclear aromatic hydrocarbons, pesticides and herbicides.
From CHF 693.00*

Capillary columns GC BP5MS
5% Phenyl Polysilphenylene-siloxane. For 5% GC-MS analysis and general purpose MS analysis. Suitable replacement for: DB-5ms, ZB-5ms, Rxi-5Sil MS, VF-5ms, CP-Sil 8 CB.
From CHF 553.85*

Capillary columns HT5
5% Phenyl Polycarborane siloxane. Ultra-high temperature columns for simulated distillation applications, general hydrocarbon profiles, pesticides, herbicides and for GCMS applications.
From CHF 624.70*

OPTIMA® 5 MS capillary columns for GC
5% diphenyl - 95% dimethylpolysiloxanenonpolar phase with low bleeding, deal for GC/MS and ECD applications and general analyses at trace level perfect inertness for basic compounds.Similar phases: DB-5 MS, HP-5 MS, Ultra-2, Equity-5, CP-Sil 8 CB low bleed/MS, Rtx-5SIL-MS, Rtx-5 MS, 007-5 MS, BPX5, MDN-5S, AT-5 MS, VF-5 MS.max. temperature for isothermal operation: 340°C, max. temperature for short isotherms in a temperature programme: 360 °CCustom-made columns to your specifications available on request.Each column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules. Column ends are melted or closed with septa, and thus protected from atmospheric oxygen.Additionally, we supply the corresponding test mixture with each column.
From CHF 898.60*

Optima® FFAP capillary columns for GC
polyethylene glycol 2-nitroterephthalateclose equivalent USP G25 / G35polar phaserecommended for FAME, free carboxylic acidssimilar phases: Permabond FFAP , DB-FFAP, HP-FFAP, CP-Sil 58 CB, 007-FFAP, CP-FFAP CB, Nukolfor columns with 0.10 to 0.32mm ID the max. temperature for isothermal operation is 250°C, the max. temperature for short isotherms in a temperature programme is 260°C for 0.53mm ID columns the max. temperatures are 220 and 240°C, resp.Custom-made columns to your specifications on request.Each column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules. Column ends are melted or closed with septa, and thus protected from atmospheric oxygen.Additionally, we supply the corresponding test mixture with each column.
From CHF 436.80*

Optima® 17 capillary columns for GC
phenylmethylpolysiloxane (50 % phenyl)medium polar phasepreferred applications: steroids, pesticides, drug analysesUSP G3similar phases: OV-17, DB-17, HP50+, HP17, SPB-50, SP-2250, Rtx-50, CP-Sil 24 CB, 007-17, ZB50 max. temperature for isothermal operation: 320°C, max. temperature for short isotherms in a temperature programme: 340°C, for 0.53mm ID columns the max. temperatures are 300 and 320°C, resp.In addition to this standard programme we will be happy to supply columns custom-made to your specifications.
From CHF 436.80*

Optima® 5 Amine GC capillary columns for amine separation
especially deactivated for the analysis of polyfunctional amines such as ethanolamines, amino-functionalised diols and similar compounds, which are important base materials in industrial chemistry, and shows strong tailing on standard-deactivated columns; similar phases: Rtx-5 Amine, PTA-5; USP G27 / G36; improved linearity for analyses of active components at trace levels: no amine absorptions even for aliphatic and aromatic amines at concentrations of 100 pg/peak; tested with the Optima® Amine test mixture, which among others also contains diethanolamine and propanol-pyridine (this test mixture is supplied with each column). Max. temperature for isothermal operation: 300°C, max. temperature for short isotherms in a temperature programme: 320°C.
From CHF 898.60*

OPTIMA® 1 high performance capillary columns for GC
100% dimethylpolysiloxanenonpolar phase separation of components according to boiling points thick film columns ≥3µm film are especially recommended for solvent analysis.Similar phases: Permabond® SE-30, OV-1, DB-1, SE-30, HP-1, SPB-1, CP-Sil 5 CB, Rtx-1, 007-1, BP1, MDN-1, AT-1, ZB-1, OV-101.For columns with 0.25 to 0.32mm ID and films
From CHF 782.10*

OPTIMA® 5 capillary columns for GC
5% phenyl - 95% dimethylpolysiloxane USP G27, G36 nonpaolar standard phase with large range of application similar phases: Permabond® SE-52 , SE-54, SE-52, DB-5, HP-5, SPB-5, CP-Sil 8, Rtx-5, 007-5, BP5, MDN-5, AT-5, ZB-5 for columns with 0.1 to 0.32mm ID and films
From CHF 436.80*