Counting chambers, Bürker | Type: With snap-on clips

Double net ruling, includes 2 haemocytometer glass covers, with LOT number on the packaging, labelled with: usable until, CE pursuant to IVD 98/79 EC. The ruling shows 9 large squares of 1 mm² each. These are used for counting leucocytes. Each large square is subdivided by double lines into 16 group squares with 0.2 mm sides. The group squares correspond in size to the Neubauer counting chamber, but have no further subdivisions. They are used for counting thrombocytes and erythrocytes. The double lines form mini squares with an area of 0.0025 mm2.

colorpickercolorpicker
Type: With snap-on clips

Similar products

Hand tally counter
Use for counting blood cells, bacterial colonies, drops of liquid, or any repetitive event. Tallies up to 9999. Features a quick-reset knob, lens window for easy reading, and finger ring for a secure grip. Sturdy, chrome-finished, metal housing.Dimensions: 46mm diameter x 41mm W.
From CHF 50.10*

Counting chamber, Improved Neubauer
With double ruling. Calibratable.Cell depth 0.1mm. Counting grid with 9 large squares each 1 mm². The 4 large squares in the corners for counting leucocytes are each subdivided into 16 squares with a side length of 0.25mm. The large square in the middle is subdivided into 25 squares each with a side length of 0.2mm. Each of these is further subdivided into 16 smaller squares each with a side length of 0.05 mm and an area of 0.0025mm². The 5 group squares marked with an 'E' are used to count thrombocytes and erythrocytes. All group squares have triple boundary lines on each side.
From CHF 70.20*

Counting chamber, Improved Neubauer, bright line
Bright line. With double ruling. Calibratable. Same counting grid as the Improved Neubauer cell, but with rhodium coated chamber base. Rulings are engraved into the Rhodium layer and appear bright under normal microscope settings. By altering the contrast it is possible to reverse the image under the microscope to make the rulings appear brighter or darker as required.
From CHF 144.30*

Counting chambers C-Chip, two chambers
Disposable counting chamber made of optical plastic. Dimensions: 25 x 75 mm, thickness 1,6 mm. Various applications such as blood cell counting, cell concentration measurement, sperm counting, investigation of cell viability and bacteria and fungal spore counting.No need for coverslipsReduces the risk of infectious materialsQuartz grade optical plasticGuaranteed repeatability and reliabilityIndividually wrappedTwo chambers per chip.
From CHF 207.82*

Counting chamber, Improved Neubauer
With double ruling. Calibratable. Cell depth 0.1 mm. Same ruling as Improved Neubauer, but the large square in the centre is divided into 16 squares each with a side length of 0.25 mm. Unlike the more modern Improved Neubauer counting chambers, the counting area of each group square is limited by the outermost of the triple border lines.
From CHF 58.40*

Counting chamber, Improved Neubauer
With double ruling. Calibratable.Cell depth 0.1mm. Counting grid with 9 large squares each 1 mm². The 4 large squares in the corners for counting leucocytes are each subdivided into 16 squares with a side length of 0.25mm. The large square in the middle is subdivided into 25 squares each with a side length of 0.2mm. Each of these is further subdivided into 16 smaller squares each with a side length of 0.05 mm and an area of 0.0025mm². The 5 group squares marked with an 'E' are used to count thrombocytes and erythrocytes. All group squares have triple boundary lines on each side.
From CHF 64.90*

Counting chamber according to Improved Neubauer
For analysis of cell suspensions.With double rulingIn compliance with DIN ISO 12 847Tolerance of depth of chamber max. 2 %Counting grids are engraved into two ground and polished surfaces in the chamber bottom, located between two elevated also ground and polished stages.With 2 haemacytometer cover glasses 20 x 26 x 0.4 mm
From CHF 43.00*

Counting chamber, Improved Neubauer
With double ruling. Calibratable. Cell depth 0.1 mm. Same ruling as Improved Neubauer, but the large square in the centre is divided into 16 squares each with a side length of 0.25 mm. Unlike the more modern Improved Neubauer counting chambers, the counting area of each group square is limited by the outermost of the triple border lines.
From CHF 70.20*

Counting chamber, Thoma
Double ruling. Without snap-on clips. Calibratable. Cell depth 0.1mm. Grid is the same as the grid in the centre of large square in the Neubauer chamber. The area of the small square is 0.0025mm². Since the large outer squares are not included, the Thoma system is only used to count thrombocytes and erythrocytes.
From CHF 64.90*

Counting chambers according to Fuchs-Rosenthal
For analysis of cell suspensions.With double rulingIn compliance with DIN ISO 12 847Tolerance of depth of chamber max. 2 %Counting grids are engraved into two ground and polished surfaces in the chamber bottom, located between two elevated also ground and polished stages.Individually packed
From CHF 47.80*