Skip to main content Skip to search Skip to main navigation
Menu

EC analytical columns NUCLEODUR® C18 Gravity, 5 µm

Description
NUCLEODUR® C18 - C 8 Gravity nonpolar high density phases

Available as octadecyl (C18 -USP L1) and octyl (C8 - USP L7) modifications. Pore size 110 Å.

  • Ideal for method development

  • Allows HPLC at pH extremes (pH 1 - 11)

  • Suitable for LC/MS due to low bleeding characteristics

  • Recommended for overall sophisticated analytical separations

  • Optimal for: pharmaceuticals, e.g. analgesics, antiinflammatory drugs, antidepressants, herbicides, phytopharmaceuticals, immunosppressants

Particle size 5 µm, 18 % C

Properties
Carbon content: 18 %
Eluent in column: Acetonitrile/water
Endcapped: Yes
Int. Ø: 2.0 mm
Length: 150 mm
Manufacturer Article Number: 760103.20
Material column: Stainless steel
Max. temperature resistance: 60 °C
Method: Analytical
Particle size: 5 µm
Particle type: Fully porous
Separation system: Reverse phase
USP listing: L1
Volume column: 0.45 ml
pH stability: 1 ... 11
Skip product gallery

Accessories

Macherey-Nagel GmbH & Co. KG

Macherey-Nagel GmbH & Co. KG
Guard columns for EC columns NUCLEODUR® C18Gravity, 5µm
NUCLEODUR® C18 - C 8 Gravity nonpolar high density phasesavailable as octadecyl (C18 -USP L!) and octyl (C8 - USP L7) modificationsPore size 110 Å; particle sizes 1,8µm, 3µm and 5µm for C18, 1,8 and 5µm for C87, 10, 12 and 16µm particles for preparative separations on requestcarbon content 18 %C for C18 , 11%C for C8ideal for method developmentallows HPLC at pH extremes (pH 1 - 11)suitable for LC/MS due to low bleeding characteristicsrecommended for overall sophisticated analytical separationsoptimal for: pharmaceuticals, e.g. analgesics, antiinflammatory drugs, antidepressants; herbicides; phytopharmaceuticals; immunosppressantsGuard columns for EC columns require guard column adapter EC (Cat. No. 7.081 898)
Price on request
Skip product gallery

Similar products

EC analytical columns NUCLEODUR® Sphinx RP, 5 µm
Distinct selectivity based on bifunctional surface coverage - USP L1 and USP L11Pore size 110 ÅHigh density of covalently bonded silanes for tailing-free peaks widens the scope for method developmentpH stability 1 - 10Suitable for LC/MS due low bleeding characteristicsHigh reproducibility and consistent quality due to tight QC proceduresRange of application: quinolone antibiotics, sulfonamides, xanthines, substituted aromaticsParticle size 5 µm, 15 % C
From CHF 604.80*

EC analytical columns NUCLEODUR® C18 Isis, 1.8 µm
C18 phase with special polymeric, crosslinked surface modification - USP L1Pore size 110 ÅHigh steric selectivityOutstanding surface deactivationSuitable for LC/MS due low bleeding characteristicspH stability 1 - 10Broad range of application: steroids, (o,p,m-) substituted aromatics, fat-soluble vitaminsParticle size 1.8 µm, 20 % C
From CHF 750.90*

EC analytical columns NUCLEODUR® C18 Isis, 5 µm
C18 phase with special polymeric, crosslinked surface modification - USP L1Pore size 110 ÅHigh steric selectivityOutstanding surface deactivationSuitable for LC/MS due low bleeding characteristicspH stability 1 - 10Broad range of application: steroids, (o,p,m-) substituted aromatics, fat-soluble vitaminsParticle size 5 µm, 20 % C
From CHF 604.80*

EC analytical columns NUCLEODUR® 100-5 C8 ec, 5 µm
Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Å, particle sizes 3 µm and 5 µm; 7 µm, 10 µm, 12 µm, 16 µm, 20 µm, 30 µm und 50 µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5 % C for C18, 10.5 % C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography.Octyl phases, 10.5 % C, particle size 5 µm.
From CHF 297.30*

EC analytical columns NUCLEODUR® 100-5 NH2, 5 µm
Pore size 110 Å, particle sizes 3 and 5 µm; 2.5 % C; not endcapped - USP L8Multi-mode columns (RP and NP):Normal phase chromatography (NP) with hexan, dichloromethane or 2-propanol as mobile phase for polar compounds such as substituted anilines, esters, chlorinated pesticidesReversed phase chromatography (RP) of polar compounds like sugars in aqueous-organic eluent systemsIon exchange chromatography of anions and organic acids using common buffers and organic modifiersstable against hydrolysis at low pH, working range pH 2-8, 100 % stable in water, suitable for LC-MSIdeal for:polar compounds under RP conditions (sugars, DNA bases), hydrocarbons under NP conditionsEluent in column is n-heptane for the NP mode - RP columns are delivered in acetonitrile - water. For changing the solvent system a rinsing step with THF may be necessary.Eluent in column n-heptane, particle size 5 µm.
From CHF 415.40*

EC analytical columns NUCLEODUR® 100-5 NH2-RP, 5 µm
Pore size 110 Å, particle sizes 3 and 5 µm; 2.5 % C; not endcapped - USP L8Multi-mode columns (RP and NP):Normal phase chromatography (NP) with hexan, dichloromethane or 2-propanol as mobile phase for polar compounds such as substituted anilines, esters, chlorinated pesticidesReversed phase chromatography (RP) of polar compounds like sugars in aqueous-organic eluent systemsIon exchange chromatography of anions and organic acids using common buffers and organic modifiersstable against hydrolysis at low pH, working range pH 2-8, 100 % stable in water, suitable for LC-MSIdeal for:polar compounds under RP conditions (sugars, DNA bases), hydrocarbons under NP conditionsEluent in column is n-heptane for the NP mode - RP columns are delivered in acetonitrile - water. For changing the solvent system a rinsing step with THF may be necessary.Eluent in column acetonitrile, particle size 5 µm.
From CHF 415.40*

EC analytical columns NUCLEODUR® C8 Gravity, 5 µm
NUCLEODUR® C18 - C 8 Gravity nonpolar high density phasesAvailable as octadecyl (C18 -USP L1) and octyl (C8 - USP L7) modifications. Pore size 110 Å.Ideal for method developmentAllows HPLC at pH extremes (pH 1 - 11)Suitable for LC/MS due to low bleeding characteristicsRecommended for overall sophisticated analytical separationsOptimal for: pharmaceuticals, e.g. analgesics, antiinflammatory drugs, antidepressants, herbicides, phytopharmaceuticals, immunosppressantsParticle size 5 µm, 11 % C
From CHF 604.80*

EC analytical columns NUCLEODUR® C8 Gravity, 1.8 µm
NUCLEODUR® C18 - C 8 Gravity nonpolar high density phasesAvailable as octadecyl (C18 -USP L1) and octyl (C8 - USP L7) modifications. Pore size 110 Å.Ideal for method developmentAllows HPLC at pH extremes (pH 1 - 11)Suitable for LC/MS due to low bleeding characteristicsRecommended for overall sophisticated analytical separationsOptimal for: pharmaceuticals, e.g. analgesics, antiinflammatory drugs, antidepressants, herbicides, phytopharmaceuticals, immunosppressantsParticle size 1.8 µm, 11 % C.
From CHF 750.90*

EC analytical columns NUCLEODUR® Sphinx RP, 3 µm
Distinct selectivity based on bifunctional surface coverage - USP L1 and USP L11Pore size 110 ÅHigh density of covalently bonded silanes for tailing-free peaks widens the scope for method developmentpH stability 1 - 10Suitable for LC/MS due low bleeding characteristicsHigh reproducibility and consistent quality due to tight QC proceduresRange of application: quinolone antibiotics, sulfonamides, xanthines, substituted aromaticsParticle size 3 µm, 15 % C
From CHF 750.90*

EC analytical columns NUCLEODUR® 100-5 C18 ec, 5 µm
Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Å, particle sizes 3 µm and 5 µm; 7 µm, 10 µm, 12 µm, 16 µm, 20 µm, 30 µm und 50 µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5 % C for C18, 10.5 % C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography.Octadecyl phases, 17.5 % C, particle size 5 µm.
From CHF 297.30*