Skip to main content Skip to search Skip to main navigation
Menu

Extractors for Soxhlet extraction

Description
Extractors with specially developed siphon tubes guarantee uniform extraction cycles. Extractors with stopcock (type H) eliminate the additional distillation after extraction.

Properties
Manufacturer Article Number: B00217970
Type: EZ 100 / H
UNSPSC: 41-10-48-06
Volume ml: 100
Skip product gallery

Similar products

LLG-Extraction thimbles, cellulose
Neutral and fat free. With excellent retention capacity. Ash content
From CHF 41.25*

Extraction thimbles, Cellulose
Supplied in packs of 25. Dimensions given are nominal internal diameter x external length in mm.
From CHF 144.00*

Extraction Thimbles, cellulose
For reliable and fast analysis in the areas of food control and environmental monitoring. Suitable for Soxhlet-type, Tecator-type or similar devices, to extract certain components out of solid material with an appropriate solvent.Made of pure cellulose that is totally free from binding elementsHigh purity of selected cellulose guarantees reliable and replicable resultsThe consistent high porosity ensures fast flow throughHigh fitting accuracy for all available extraction systemsWall thickness 1.3 mm at thimbles with ≤35 mm inner diameter, 1.7 mm at thimbles with >35 mm inner diameterFor two systemsGrade 900: Soxhlet Extraction, Grade 901: Tecator Extraction
From CHF 104.00*

Extraction thimbles MN 645, pure cellulose
Fat determination in food and feedDetermination of binder content in asphaltAnalysis of soil contaminantsDetermination of additives in rubber and elastomers
From CHF 115.70*

Extraction Thimbles, Grade 603 G, glass fibre
Resistant to temperatures up to 500 °CAnalysis of hot and acidic gases, including emission control and smoke stack gas monitoringSoxhlet extractionAnalysis of pesticide residuesDetermination of oil/fat content of foodsAnalysis of oil and grease in solid wastes
From CHF 256.00*

Extraction apparatuses acc. to Soxhlet, with Dimroth condenser, DURAN® tubing
The complete apparatuses are consisting of: extractor in compact and robust design, with flask connection NS 29/32, made of DURAN® tubing, Dimroth condenser, with thread GL 14, made of DURAN® tubing, round bottom flask, material: DURAN®
From CHF 205.00*

Cellulose-Extraction thimbles Grade 603
Manufactured in pure cellulose according to DIN 12449.
From CHF 137.00*

Short Distilling Apparatus
For micro quantities, modified distilling link, Göttingen type, for loss-free working with small quantities of substances, consisting of:Microdistill with 2 joints cone NS 14,5/23 and 1 joint NS 10/19Distribution spider with 3 cones NS 14,5/23 and 1 socket NS 14,5/233 small flasks, 5 ml, NS 14,5/23Two neck flask, 50 ml, with 2 joints NS 14,5/23Stopper NS 14,5/23Thermometer with ground joint, NS 10/19, 0 to + 250 °C5 ground joint clamps NS 14,5
From CHF 650.15*

Extraction thimbles, Borosilicate glass
Recommended for Soxhlet extraction with solvents, which are incompatible with cellulose fibres and for filtration of air and gas streams.Made of 100 % pure borosilicate fibres, without binding elementsHigh loading capacity and highly permeable to airThickness is 1.5 mm (diameter < 33 mm)High retention of small particles, > 99 % according to BS 4400Good stability at high temperatures up to 500 °CRecommended for hot, moist, and acidic gasesGravimetric determination of particles in hot gasesFurther sizes on request.
From CHF 184.00*

behrotest® CF 2+2 and CF 6, Semi-automatic Crude Fibre Extraction
They are ideally suited for:total crude fibre determination (part of the Weender animal feed analysis as performed in Europe)neutral detergent fibre and acid detergent fibre determination (NDF and ADF according to Van Soest)acid detergent lignin determination (ADL according to Van Soest)different fractions of fibre (cellulose, hemicellulose and pectin) behrotest® semi-automatic crude fibre extraction units simplify everday life in the lab:Easy operationThe analyst is guided through the procedure by messages on the display.behr ABP ("acknowledge before proceeding") method for optimum analytical safety. Possible manual operation of air and suction pumps.
From CHF 7,501.00*