Skip to main content Skip to search Skip to main navigation
Menu

Optima® 624 LB capillary columns for GC

Description
6% cyanopropyl-phenyl - 94% dimethylpolysiloxane

USP G 43
medium polar phase
low bleed columns for halogenated hydrocarbons, volatiles, aromatic compounds, solvents etc.
similar phases: HP-624, HP-VOC, DB-624, DB-VRX, SPB-624, CP-624, Rtx-624, Rtx-Volatiles, 007-624, BP624, VOCOL

max. temperature for isothermal operation: 280°C, max. temperature for short isotherms in a temperature programme: 300°C


Custom-made columns to your specifications available on request.
Each column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules.
Column ends are melted or closed with septa. Additionally, we supply the corresponding test mixture with each column.
Properties
Film thickness: 1.8 µm
Int. Ø: 0.32 mm
Length: 50 m
Manufacturer Article Number: 726786.50
Material column: Quartz glass
Max. temperature programme: 300 °C
Polarity: Mid-polar
Temperature max isotherm: 280 °C
USP listing: G43
Skip product gallery

Similar products

Capillary columns GC SolGel-1ms™
100% Dimethyl Polysiloxane in a SolGel matrix. Suitable Replacement for: DB-1, DB-Petro, HP-1, HP-1MS, Rtx-1, Ultra-1, SPB-1, SPB-1 Sulfur, Petrocol DH, CP-Sil 5CB, VB-1, ZB-1, VF-1ms.Less bleedNon-polarHighly inertSame selectivity as BP1
From CHF 1,016.00*

Capillary columns BPX1-SIMD
100% Dimethyl Polysiloxane. For high temperature hydrocarbon analysis and ASTM methods D2887 and D6532. Suitable replacement for: DB-2887, DB-HT Sim Dis, HP-1, Petrocol 2887, Petrocol EX2887, Rtx-2887.Non-polarLow bleed
From CHF 667.00*

Capillary columns GC BP1
100% Dimethyl Polysiloxane. General purpose GC column for all routine analyses such as hydrocarbons, aromatics, pesticides, phenol, herbicides and amines. Suitable replacement for: DB-1, DB-Petro, HP-1, HP-1MS, Rtx-1, Ultra-1, SPB-1, SPB-1 Sulfur, Petrocol DH, CP-Sil 5CB, VB-1, ZB-1, VF-1ms.Low bleedNon-polar
From CHF 585.00*

Capillary columns GC BP1 PONA
100% Dimethyl Polysiloxane. For the analysis of petroleum products. Suitable Replacement for: Petrocol DH, DB-Petro, HP-PONA, AT-Petro, Elite-PONA, ZB-1, 007-1-100-0.5F, Rtx-1PONA, CP Sil PONA.Non-polar phase for PONA analysisDetailed hydrocarbon analysis according to ASTMCrosslinked and washableVery high resolving power columns for complex samples
From CHF 2,041.00*

Capillary columns BP624
Cyanopropylphenyl Polysiloxane. For the analysis of volatile components of drinking water, chlorinated hydrocarbons, solvents and for the EPA method 624, USP G43 methods, SW-846 and 8240 / 8260 methods. Suitable replacement for: DB-624, OV-624, AT-624, HP-VOC, CP-Select624CB, 007-624, Rtx-Volatiles, VOCOL, ZB-624.
From CHF 1,180.00*

Capillary columns GC CYDEX-B™
Permethylated Beta-Cyclodextrin (Chiral). Suitable replacement for: Cyclodex-B, Rt-BDEXm, LIPODEX C. Phase for the separation of chiral compound e.g. separation of enantiomeric compounds found in natural products.
From CHF 1,232.00*

Capillary columns BPX-Volatiles
Cyanopropyl Polysilphenylene. Polar phase. For environmental analyses, volatile organic substances, alcohol analyses and for the EPA method 624, USP G43 methods, 502.2, SW-846 and 8240 / 8260 methods. Suitable replacement for: DB-VRX, HP-624, OPTIMA 624, ELITE-624, 007-624, RTXVOLATILES, SPB-624, TRV1, CPSIL 13 CB, VOCOL, VB-624, CP-624.
From CHF 1,130.00*

Capillary columns GC BP21
Nitroterephtalic acid modified PEG. For low molecular weight acids, alcohols, aldehydes, acrylates and ketones. Suitable replacement for: DB-FFAP, HP-FFAP, Stabilwax-DA, CPWax-58CB.Polar phaseAble to be solvent rinsed (water or methanol are not recommended for rinsing)
From CHF 1,078.00*

Capillary columns GC BPX90
90% Cyanopropyl Polysilphenylene-siloxane. For the fast separation of fragrances, aromatics, pesticides, PCB, isomers of fatty acid methyl esters.Bonded phaseHighly polarThermally stableAble to be solvent rinsed
From CHF 789.00*

Capillary columns GC BPX70
70% Cyanopropyl Polysilphenylene-siloxane. Able to be solvent rinsed. Industry standard column for fatty acid methyl esters, carbonhydrates, pharmaceuticals, GC/MS applications. Suitable alternative to: DB-23, Rtx-2330, SP-2330, CP-Sil 88, SP2380, HP-23.
From CHF 629.00*