Photometers MD 110 | Description: MD 110, chlorine, pH, cyanuric acid, alkalinity-m, liquid reagents

Photometer for the analysis of determined parameters in drinking, industrial and waste water. Different models are available for common analyses as well as for special applications.
  • Ergonomic, waterproof design
  • Accurate, reproducible measurement results
  • User calibration and single point calibration
  • Measurement results are displayed directly in ABS or %T
  • Zero value remains valid for all tests with the same sample thanks to the one-time zero (OTZ) function
  • Automatic storage of measured values with time and date stamp and optional data transfer (IRiM module)
  • Bluetooth® interface
  • Scroll memory
  • Automatic shutdown
  • Adjustment function display

Scope of supply: Photometer, carrying case, reagents for 100 tests, cuvettes, batteries, standard accessories

Further photometers available on request.


colorpickercolorpickercolorpickercolorpicker

Specifications
Optics:
Highly precise interference filters, LED
Wavelengths:
530 / 560 / 610 / 430 / 580 / 660 nm
Wavelength accuracy:
±1 nm
Photometric range: pH:
0.005 A 6,5 - 8,4
Data memory:
16 measurements
Dimensions (W x D x H):
75 x 155 x 35 mm
Weight:
260 g
Power supply:
4 x AAA micro batteries
IP code:
IP 68

Hazardous Substance Data
GHS
colorpickercolorpickercolorpicker
Signal word
Achtung
H-Satz
EUH210, H290, H315, H319, H226
P-Satz
P234, P280, P302+P352, P305+P351+P338, P233
SDS
Link
Description: MD 110, chlorine, pH, cyanuric acid,alkalinity-m, liquid reagents
Measuring range: 5 ... 200 mg/l CaCO30.02 ... 4.0 mg/l Cl210 ... 160 mg/l CyA

Other customers also bought

Tintometer GmbH
Photometers MD 110
Photometer for the analysis of determined parameters in drinking, industrial and waste water. Different models are available for common analyses as well as for special applications.Ergonomic, waterproof designAccurate, reproducible measurement resultsUser calibration and single point calibrationMeasurement results are displayed directly in ABS or %TZero value remains valid for all tests with the same sample thanks to the one-time zero (OTZ) functionAutomatic storage of measured values with time and date stamp and optional data transfer (IRiM module)Bluetooth® interfaceScroll memoryAutomatic shutdownAdjustment function displayScope of supply: Photometer, carrying case, reagents for 100 tests, cuvettes, batteries, standard accessoriesFurther photometers available on request.SpecificationsOptics:Highly precise interference filters, LEDWavelengths:530 / 560 / 610 / 430 / 580 / 660 nmWavelength accuracy:±1 nmPhotometric range: pH:0.005 A 6,5 - 8,4Data memory:16 measurementsDimensions (W x D x H):75 x 155 x 35 mmWeight:260 gPower supply:4 x AAA micro batteriesIP code:IP 68
Price on request

Similar products

Tube tests NANOCOLOR® Sulfide / Sulfite / Sulfate
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 103.00*

Tube tests NANOCOLOR® ortho- and total Phosphate
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 128.22*

Tube tests NANOCOLOR® COD
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.DIN ISO 15705
From CHF 113.40*

Photometers MD 100
The Lovibond® MD 100 Photometers are designed for analysis of different parameters in drinking water, industrial process water and waste water. With a total of more than 30 different types, instruments are available for routine testing as well as for special applications. The MD 100 uses high quality interference filters with long-life LEDs as a light source without any moving parts in a transparent sample chamber. The units supply accurate, reproducible results very quickly. Other major advantages include ease of operation, ergonomic design, compact dimensions and safe handling. Provided with calibration and software-based adjustment options the MD 100 is suitable for use as a testing instrument. The tests are conducted using either Lovibond® tablet reagents with long-term stability and a shelf life of 5 or 10 years, VARIO powder reagents or using liquid reagents.Optics: High-quality Interference FiltersWavelength accuracy: ±1 nm.Power supply: 4 micro batteries (AAA), capacity approx. 17 hours or 5000 tests.Automatic switch-off.LCD Display (backlit on keypress).Internal ring memory for 16 data sets.Dimensions (L x W x H): 155 x 75 x 35 mm.Scope of supply: Photometer in a plastic carrying case, with reagents for 100 tests, cells, batteries and standard accessories.Optional: IRiM - infrared interface module for data transfer to computer or printer.*Delivery without reagents for measuring range 0.1 - 10 mg/l Cl2.**24mm diam. glass cell***10mm diam. multi cell-2
Price on request

Accessories NANOCOLOR®
*additional cable required**additional mains adapter required
From CHF 18.40*

Tube tests NANOCOLOR® Ammonium
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 114.40*

Reagents VARIO for Photometer Lovibond®and HACH®
Suitable for Lovibond®Photometers as well as for Photometers of company HACH®**HACH® is a registered trademark of HACH® Company, Loveland, Colorado. Using brand HACH® contains no indication of a connection to this company or to a possible agreement of HACH® Company to composition, examination or suitability for use in spectrophotometers or other equipment or systems, which are sold under the brand HACH®.
Price on request