Skip to main content Skip to search Skip to main navigation
Menu

Photometers MD 200

Description
Benchtop devices suitable for mobile use. For precise water control through high-precision optics and high-quality interference filters with long-term stable LEDs as light sources.
  • Automatic shutdown
  • Real time clock and date
  • Adjustment function display
  • Illuminated LCD-display

Further photometer versions available on request.


Specifications
Measurement cycle:
approx. 3 seconds (method dependent)
Optics:
Temperature compensated LED and photosensor intensifier in a waterproof sample chamber
Keyboard:
4-key polycarbonate film, splashproof
Dimensions (W x D x H):
110 x 190 x 55 mm
Weight:
455 g
Power supply:
4 x AA
IP code:
IP 68
pH:
6.5 - 8.4

Hazardous Substance Data
GHS
colorpickercolorpickercolorpicker
Signal word
Achtung
H-Satz
EUH210, H290, H315, H319, H226
P-Satz
P234, P280, P302+P352, P305+P351+P338, P233
SDS
Link
Properties
Description: MD 200, Chlorine, bromine, pH, cyanuric acid,alkalinity-m, calcium hardness, reagent tablets (OTZ)
GHS: GHS05, GHS07, GHS02
Manufacturer Article Number: 2861902
Measuring range: 0.01 ... 6.0 mg/l CI20.01 ... 10.0 mg/l CI20.05 ... 13 mg/l Br0 ... 160 mg/l Cys5 ... 200 mg/l CaCO3 (TA)0 ... 500 mg/l CaCO3 (CaH)
Skip product gallery

Similar products

Tube tests NANOCOLOR® Sulfide / Sulfite / Sulfate
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 107.20*

Tube tests NANOCOLOR® ortho- and total Phosphate
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 133.40*

Tube tests NANOCOLOR® COD
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.DIN ISO 15705
From CHF 114.60*

Photometers MD 100
The Lovibond® MD 100 Photometers are designed for analysis of different parameters in drinking water, industrial process water and waste water. With a total of more than 30 different types, instruments are available for routine testing as well as for special applications. The MD 100 uses high quality interference filters with long-life LEDs as a light source without any moving parts in a transparent sample chamber. The units supply accurate, reproducible results very quickly. Other major advantages include ease of operation, ergonomic design, compact dimensions and safe handling. Provided with calibration and software-based adjustment options the MD 100 is suitable for use as a testing instrument. The tests are conducted using either Lovibond® tablet reagents with long-term stability and a shelf life of 5 or 10 years, VARIO powder reagents or using liquid reagents.Optics: High-quality Interference FiltersWavelength accuracy: ±1 nm.Power supply: 4 micro batteries (AAA), capacity approx. 17 hours or 5000 tests.Automatic switch-off.LCD Display (backlit on keypress).Internal ring memory for 16 data sets.Dimensions (L x W x H): 155 x 75 x 35 mm.Scope of supply: Photometer in a plastic carrying case, with reagents for 100 tests, cells, batteries and standard accessories.Optional: IRiM - infrared interface module for data transfer to computer or printer.*Delivery without reagents for measuring range 0.1 - 10 mg/l Cl2.**24mm diam. glass cell***10mm diam. multi cell-2
From CHF 508.00*

Reagent solutions for photometers Lovibond®
Solution with 15 ml or refill bottle with 100 ml.* Refill bottle
From CHF 16.10*

Photometer PrimeLab 2.0 starter-kit, all parameters activated
The photometer with 18 different wavelengths (3 sensors with 6 wavelengths) covers the full VIS-spectrum as well as key parts of UV and IR spectrum. LEDs are set up at 180° as well as at 90° to enable NTU-Turbidity, PTSA and Fluorescein measurements as well.5.5" colour HD touch-displayMore than 140 different parameter methodsPlease order reagents separatelyAuto-calibration functionIntelligent OTZ (One-Time-Zero) functionCan be used with 1 ml, 16 mm and 24 mm cuvettesData management with free software (LabCOM) / app in free cloud including individual accounts and reporting systemScope of supply:Multitest Photometer PrimeLab 2.0, carrying case, 10 x 24 mm/10 ml glass cuvettes with lid, light-shield, 16 and 24 mm cuvette adapters, stirring rod, 10 ml plastic syringe, cleaning brush, battery-charger with USB-cable (type C), 20 ml luer lock syringe, filter adapter, 2 cans with 50 filter papers, 100 ml can with lidSpectral range:390 ... 950 nm, 18 wavelengthsAmbient temperature:5 ... 45 °CRel. humidity:30 ... 90 %Internal memory:150000 measurementsDatatransfer:WiFi, GSMSoftware:LabCOM software, LabCOM App, LabCOM CloudPower supply:8500 mA Li-Io battery, 5 V power supply with adaptersWarranty:2 years
From CHF 2,389.00*