RESPIROMETRIC Sensor System 6 BOD | Description: RESPIROMETRIC Sensor System 6 BOD without Databox™

Measuring systems for the reliable determination of 90 to 4000 ppm BOD, BOD5 and BOD7 for the control of water and wastewater quality.

Complete with sensor heads and multi-position magnetic stirring station for performing aerobic and anaerobic respiration tests. Measurement data is transmitted wirelessly from the RESPIROMETRIC sensor head to a PC via the Databox™. The Databox™ can store results from up to 48 RESPIROMETRIC sensors. With the RESPIROSoft™ software, these measurement data can be evaluated and monitored on the PC. Alternatively, the Databox™ can be connected to the Velp Ermes cloud platform. After registration, measurement data can also be monitored and analysed from mobile devices.

  • 4-digit LED display

  • 2-button user interface

  • Results available in BOD (mg/l) and pressure (mbar)

  • Automatic conversion of pressure results into BOD

  • Wireless transmission of data to the PC (Wlan)


Scope of supply: 6-position magnetic stirring station, 6 x sensor heads incl. batteries, 6 x 500 ml amber bottles, 6 x KOH containers, 6 x magnetic stirring bars


BOD range:
90 ... 4000 ppm
Pressure range:
500 ... 2000 mbar
Measuring period:
5 ... 30 days
Dimensions sensor (W x D x H):
50 x 70 x 70 mm
Dimensions stirring station (W x D x H):
270 x 185 x 300 mm
Weight sensor:
80 g
Weight stirring station:
1 kg
Power supply sensor:
2 x CR 2430
Power supply stirring station:
230 V, 50 ... 60 Hz
IP code:
IP54
Description: RESPIROMETRIC Sensor System 6 BOD without Databox™
Dual Use: 0
Manufacturer Article Number: SB10200146

Accessories

Velp Scientifica SRL
Ermes cloud connection
Subscription code for connecting up to 10 devices to the VELP Ermes Cloud Platform.
From CHF 318.63*

Similar products

Dissolved oxygen bottles, Winkler pattern
Winkler pattern. Soda-lime glass.For determination of dissolved oxygen in water. The measured capacity is specified to ± 0,01ml. With white labelling area. Solid, bevelled glass stopper, secured with an accessory spring clip. Each bottle is adjusted to the relevant stopper. Stoppers and bottles are therefore not interchangeable. Each bottle and its stopper is marked with a unique, matching identification number.
From CHF 33.90*

Thermostatic cabinets
The incubators from Lovibond® are designed for continuous tempering for different applications, mainly for the determination of BOD, the storage of wastewater samples, and the determination of enzymatic activity. The temperature range is +2°C up to +40°C and can be regulated in steps of 0,1°C. Temperature tolerance is defined with +/- 1°C respectively +/- 0,5°C (at 20°C). Low engergy consumption due to reinforced isolation. The interior of the cabinets is equipped with sockets for connecting stirrers. Illuminated LED display with actual / setpoint display.Temperature range 2 °C to 40 °C, continuously adjustable in steps of 0.1 °CLow power consumptionIlluminated LED display of preset and current temperaturesIdeal for BOD determination at 20 °CPower sockets inside the incubatorStandard door or glass doorSpecificationsCoolant:R134aFan:Axial, delivery rate 320m3/hPower supply:220-230V/50Hz* With glass door
From CHF 2,035.00*

Overflow Measuring Flask for OxiTop®
Glass measuring flask with fixed volume doses for the easy and accurate measurement of the required sample volume for respirometric BSB measurements.
From CHF 66.20*

Measuring heads OxiTop®-i
Menu-operated measuring heads. Output of the BOD measurement values directly on the display.3 operating buttonsBacklit graphic LCDControl LEDVolume pre-selectionMeasurement duration selectable (1 to 7 days)Display of measuring curveDisplay of current readings
From CHF 700.20*

RESPIROMETRIC Sensor System 6 BOD
Measuring systems for the reliable determination of 90 to 4000 ppm BOD, BOD5 and BOD7 for the control of water and wastewater quality.Complete with sensor heads and multi-position magnetic stirring station for performing aerobic and anaerobic respiration tests. Measurement data is transmitted wirelessly from the RESPIROMETRIC sensor head to a PC via the Databox™. The Databox™ can store results from up to 48 RESPIROMETRIC sensors. With the RESPIROSoft™ software, these measurement data can be evaluated and monitored on the PC. Alternatively, the Databox™ can be connected to the Velp Ermes cloud platform. After registration, measurement data can also be monitored and analysed from mobile devices.4-digit LED display2-button user interfaceResults available in BOD (mg/l) and pressure (mbar)Automatic conversion of pressure results into BODWireless transmission of data to the PC (Wlan)Scope of supply: 6-position magnetic stirring station, 6 x sensor heads incl. batteries, 6 x 500 ml amber bottles, 6 x KOH containers, 6 x magnetic stirring barsBOD range:90 ... 4000 ppmPressure range:500 ... 2000 mbarMeasuring period:5 ... 30 daysDimensions sensor (W x D x H):50 x 70 x 70 mmDimensions stirring station (W x D x H):270 x 185 x 300 mmWeight sensor:80 gWeight stirring station:1 kgPower supply sensor:2 x CR 2430Power supply stirring station:230 V, 50 ... 60 HzIP code:IP54
From CHF 3,964.05*

RESPIROMETRIC Sensor System 6, plastic biodegradability
Measuring systems for the reliable determination of the degree of biodegradability of plastic materials in an aqueous medium.Complete with sensor heads and multi-position magnetic stirrer for performing aerobic respiration tests. Measurement data is transmitted wirelessly from the RESPIROMETRIC sensor head to a PC via the Databox™. The Databox™ can store results from up to 48 RESPIROMETRIC sensors. With the RESPIROSoft™ software, these measurement data can be evaluated and monitored on the PC. Alternatively, the Databox™ can be connected to the Velp Ermes cloud platform. After registration, measurement data can also be monitored and analysed from mobile devices.4-digit LED display2-button user interfaceResults available in pressure (mbar)Magnetic stirrer with timer and electronic speed controlWireless transmission of data to the PC (Wlan)Scope of supply: 6-position magnetic stirrer MULTISTIRRER Digital, 6 x sensor heads incl. batteries, 6 x 1000 ml bottles, 6 x kits for plastic biodegradability analysis, 6 x magnetic stirring barsPressure range:500 ... 2000 mbarMeasuring period:1 ... 180 daysDimensions sensor (W x D x H):50 x 70 x 70 mmDimensions magnetic stirrer (W x D x H):230 x 370 x 51.5 mmWeight sensor:80 gWeight magnetic stirrer:1.75 kgPower supply sensor:2 x CR2430Power supply magnetic stirrer:100 ... 240 V, 50 ... 60 HzIP code:IP54Speed range magnetic stirrer:80 ... 1500 rpmStirring position distance magentic stirrer:100 mm
From CHF 5,163.57*

BOD-Measurement-System BD 600
BOD measurement is an important measurement of the effects of domestic and industrial waste water on sewage plants and outflow points. The sensor system BD 600 is a 6 sample system that allows precise measurements of BOD based on the manometric principle. Manometric respirometers relate oxygen uptake to the change in pressure caused by oxygen consumption while maintaining a constant volume. Due to the modern integral pressure sensors, it is not necessary to use mercury for the measurements. The BOD values are stored automatically in the sensor memory at regular intervals and can be called up on the large-format display at any time without the need for time-consuming conversion using factors. This means that test series that end on a Sunday can be evaluated during the following week without any problem. Measurement series can be stored on USB stick/ SD card or transferred via USB cable to evaluate the data on a computer. The measurement period is user-selectable between 1 and 28 days to suit the application. While short measurement periods are useful for scientific applications, standard BOD measurements typically extend over a period of 5 days - and manometric determination of OECD, for example, generally takes place over a period of 28 days.Scope of supply:BD 600, complete unit with 6 or 12* sensor heads and control unit with batteriesPower supply unit incl. Y-cable for common power supply of BD 600 and stirring unitInductive stirring unit6 or 12* sample bottles6 or 12* rubber gaskets6 or 12* magnetic stirring rods1 overflow flask, 157 ml1 overflow flask, 428 ml1 bottle, 50 ml potassium hydroxide solution1 bottle, 50 ml nitrification inhibitor solution1 instruction manualremote controlSpecificationsMeasuring principle:respirometric, electronic pressure sensorRanges:0 - 40, 0 - 80, 0 - 200, 0 - 400, 0 - 800, 0 - 2000, 0 - 4000 mg/l O2Measurement period:User-selectable, between 1 and 28 daysPower supply:100-240 V, battery buffered or via power supply using Y-cableProtection class:IP 54 (sensor head)Interface:USB host port (USB stick), USB device port (computer), SD cardClock:Real timeApplication:BOD5 / BODF / OECD301F* 6 or 12 depending on BOD-System (BD600 or BD606)
Price on request