Turbidity meter Turb® 750 T | Type: Turb® 750 T

High-precision turbidity measuring devices for standardized measurement in drinking water and laboratory and industrial applications with AQA-based turbidity measurement.

  • Backlit graphic display, 160 x 104 Pixel

  • Quick response time

  • Multiple measurements and evaluation of the measurement data with the intelligent reproducibility and plausibility check (IRPC)(IRPC)

  • Function keys

  • Comfortable menu-guided 3-point standard calibration

  • Flexible calibration with 2 to 5 user-defined calibration points

  • QuickCAL: 1-point-calibration at 10 NTU

  • AQA, calibration interval and records with PC-documentation and LIMS connection

  • For round cells with diam. 28 mm, volume min. 15 ml

  • With RS 232 interface, USB


Scope of supply: Turbidity meter, 4 x batteries, wide range power supply, cable USB-A to USB-B mini, 6 x empty vials, sticker for orientation marking, calibration kit, cloth, manuals, CDROM with manual and PC software Turb® Data, inspection protocol

Nephelometrical turbidity measurement according to US EPA 180.1.

colorpicker

Specifications
Memory:
2500 data sets
Operating temperature:
5 ... 55 °C
Dimensions (W x D x H):
190 x 290 x 80 mm
Weight:
1.1 kg
Power supply:
4 x 1.5 V AA batteries, 90 ... 250 VAC

Specifications
Light source:
Tungsten lamp (white light)
Measuring range:
0 ... 1100 NTU
Resolution:
0.01 NTU in the range 0.00 ... 9.99 0.1 NTU in the range 10.00 ... 99.99 1 NTU in the range 100 ... 1000
Accuracy:
0.01 NTU or ±2 % of measured value, ±3 % in the range 500 ... 1100
Reproducibility:
0.5 % of measured value
Type: Turb® 750 T

Similar products

Sedimentation cone, plastic, SAN
Imhoff pattern. DIN 12672. Transparent SAN (Styrene acrylonitrile). With screw cap for draining the contents. Temperature-resistant up to max. 85°C.Graduations, ml:Subdivisions, ml0 to 20.12 to 100.510 to 1001.5100 to 30010300 to 100050
From CHF 47.40*

Accessory holders for sedimentation cones, PVC
Imhoff pattern, solid grey PVC. Stable design.
From CHF 198.80*

Imhoff Sedimentation cones, borosilicate glass 3.3
Manufactured from borosilicate glass 3.3 according to sedimentation tests according to DIN 12672 standard. Featured with volume graduation of 1000 ml. Volume graduations and inscriptions are printed with white enamel.Graduations, ml:Subdivisions ml:0 to 20.12 to 100.510 to 401.040 to 1002.0100 to 100050.0
From CHF 95.20*

Secchi Disk
For determining the depth of visibility and light permeability of water. Sturdy design made of strong, hard-wearing plastic. Lead weight for better lowering. The approx. 15 cm high rod is fitted with an eyelet for fastening the lowering engine. The lowering line is marked in intervals of 100 cm with figures from 1 to 10 and in between additionally with line markings each 50 cm for better reading of the depth of visibility while the disk is being lowered.Lowering line, please order separately.
From CHF 37.00*

Turbidity meter TB 211 IR
The compact infrared turbidity meter TB 211 IR is designed to allow fast, precise on-site testing. The unit measures the scattered light at an angle of 90°, as stipulated in EN ISO 7027. The wide measuring range from 0.01 to 1100 TE/F = NTU = FNU permits use of the unit for various media, ranging from drinking water to waste water.As infrared light is used for measurement, the unit can be used to test both coloured and colourless liquids. The standards required for calibration of the unit are also supplied. A second adjustment mode allows alternative adjustment with user-defined turbidity standards.measuring ranges from 0.01 to 1100NTU (autorange)measurement with infrared light at an angle of 90°easy operation600 tests between battery chargesScope of supply: Turbidity meter, 4 turbidity standards
Price on request

Turbidity Standards
Highly accurate turbidity standards composed of suspended microspheres, suitable for Instrument calibration and control of all turbidity meters. Stable, shelf life of 2 years (from Date of Manufacturing). NIST traceable, US EPA approved and tested in compliance with ISO 7027. HDPE bottles of 100 ml.Two ranges available:Ratio range for Ratio Turbidity Measuring instruments (measure of the scattered light from the sample at a 90° angle from the incident light, plus at additional angles (several detectors)Non Ratio for Non Ratio Turbidity Measuring instruments will measure the scattered light from the sample at a 90° angle from the incident light (one detector)
Price on request

Turbidity Standards Formazine
For all turbidity meters.
Price on request

Flocculation tester ET 730 / ET 740 / ET 750, bench top
Designed for efficiency testing of flocculation or precipitation agents.For use in laboratories. Model ET 730 portableIlluminated back panel for glare-free observation of the samplesModels ET 740 and ET 750 with continuously variable stirring speedSpeed of ET 730 can be adjusted to 20, 40, 50, 100 and 200 min-1Timer feature and digital displayHeight adjustment of the stirring blades during operationFor beakers with 1000 to 1500 ml volume, tall and low formSpecificationsSpeed controlAL30: AL40 + AL50:20, 40, 50, 100, 120 min-1 10 ... 300 min-1 (stepless)TimerAL30: AL40 + AL50:0 ... 30 minutes (continuous) 0 ... 999 min or 0 ... 99 h (continuous)Power Supply:100 ... 240 V, 50/60 Hz
From CHF 1,850.00*

Calibration Kit for Turbidimeter Eutech™ TN-100
Calibration kit includes 4 x 60 ml standard solutions (0.02, 20.0, 100, 800 NTU).
From CHF 346.60*