VarioPrep columns for preparative HPLC NUCLEODUR® Sphinx RP, 5µm | Type: 10 mm i.d.

distinct selectivity based on bifunctional surface coverage - USP L1 and USP L11
pore size 110 Å, particle sizes 1,8µm, 3µm and 5µm; 14 %C
high density of covalently bonded silanes for tailing-free peaks widens the scope for method development
pH stability 1 - 10
suitable for LC/MS due low bleeding characteristics
high reproducibility and consistent quality due to tight QC procedures
range of application: quinolone antibiotics, sulfonamides, xanthines, substituted aromatics



10 x 8mm ID VarioPrep guard columns require the 8mm VP guard column holder and are suited for 8 and 10mm ID VP columns,
Manufacturer Article Number: 762390.80
Type: 10 mm i.d.

Accessories

Macherey-Nagel GmbH & Co. KG
VarioPrep guard column holders and replacement parts
VarioPrep columnscolumn system for preparative HPLC manufactured from stainless steel with two adjustable end fittings, allows compensation of a dead volume, which could result at the column inlet after some time of operation, without need for opening the column, packed with NUCLEODUR® and NUCLEOSIL® spherical silica.O-rings available on request.
From CHF 343.20*

Similar products

EC analytical columns NUCLEODUR® C18 Isis, 5µm
C18 phase with special polymeric, crosslinked surface modification - USP L1pore size 110 Å, particle sizes 1,8µm, 3µm and 5µm; 20%Chigh steric selectivityoutstanding surface deactivationsuitable for LC/MS due low bleeding characteristicspH stability 1 - 10broad range of application: steroids, (o,p,m-) substituted aromatics, fat-soluble vitaminsparticle size 5µm, 20% C
From CHF 582.40*

EC analytical columns NUCLEODUR® 100-5 C8 ec, 5 µm
Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Ä, particle sizes, 3µm and 5µm; 7µm, 10µm, 12µm, 16µm, 20µm, 30µm und 50µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5%C for C18 , 10,5%C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography.Octyl phases, 10.5 % C, particle size 5 µm.
From CHF 282.90*

EC analytical columns NUCLEODUR® 100-5 NH2, 5µm
pore size 110 Å, particle sizes 3 and 5µm; 2,5%C; not endcapped - USP L8multi-mode columns (RP and NP)normal phase chromatography (NP) with hexan, dichloromethane or 2-propanol as mobile phase for polar compounds such as substituted anilines, esters, chlorinated pesticidesreversed phase chromatography (RP) of polar compounds like sugars in aqueous-organic eluent systemsion exchange chromatography of anions and organic acids using common buffers and organic modifiersstable against hydrolysis at low pH, working range pH 2-8, 100% stable in water, suitable for LC-MSIdeal for: polar compounds under RP conditions (sugars, DNA bases), hydrocarbons under NP conditionsEluent in column is n-heptane for the NP mode - RP columns are delivered in acetonitrile - water. For changing the solvent system a rinsing step with THF may be necessary.eluent in column n-heptane, particle size 5µm.
From CHF 395.20*

EC analytical columns NUCLEODUR® 100-5 NH2-RP, 5µm
pore size 110 Å, particle sizes 3 and 5µm; 2,5%C; not endcapped - USP L8multi-mode columns (RP and NP)normal phase chromatography (NP) with hexan, dichloromethane or 2-propanol as mobile phase for polar compounds such as substituted anilines, esters, chlorinated pesticidesreversed phase chromatography (RP) of polar compounds like sugars in aqueous-organic eluent systemsion exchange chromatography of anions and organic acids using common buffers and organic modifiersstable against hydrolysis at low pH, working range pH 2-8, 100% stable in water, suitable for LC-MSIdeal for: polar compounds under RP conditions (sugars, DNA bases), hydrocarbons under NP conditionsEluent in column is n-heptane for the NP mode - RP columns are delivered in acetonitrile - water. For changing the solvent system a rinsing step with THF may be necessary.eluent in column acetonitrile, particle size 5µm.
From CHF 395.20*

EC analytical columns NUCLEODUR® C8Gravity, 5µm
NUCLEODUR® C18 - C 8 Gravity nonpolar high density phasesavailable as octadecyl (C18 -USP L!) and octyl (C8 - USP L7) modificationsPore size 110 Å; particle sizes 1,8µm, 3µm and 5µm for C18, 1,8 and 5µm for C87, 10, 12 and 16µm particles for preparative separations on requestcarbon content 18 %C for C18 , 11%C for C8ideal for method developmentallows HPLC at pH extremes (pH 1 - 11)suitable for LC/MS due to low bleeding characteristicsrecommended for overall sophisticated analytical separationsoptimal for: pharmaceuticals, e.g. analgesics, antiinflammatory drugs, antidepressants; herbicides; phytopharmaceuticals; immunosppressantsparticle size 5µm, 11% C
From CHF 582.40*

EC analytical columns NUCLEODUR® C8Gravity, 1.8µm
NUCLEODUR® C18 - C 8 Gravity nonpolar high density phasesavailable as octadecyl (C18 -USP L!) and octyl (C8 - USP L7) modificationsPore size 110 Å; particle sizes 1,8µm, 3µm and 5µm for C18, 1,8 and 5µm for C87, 10, 12 and 16µm particles for preparative separations on requestcarbon content 18 %C for C18 , 11%C for C8ideal for method developmentallows HPLC at pH extremes (pH 1 - 11)suitable for LC/MS due to low bleeding characteristicsrecommended for overall sophisticated analytical separationsoptimal for: pharmaceuticals, e.g. analgesics, antiinflammatory drugs, antidepressants; herbicides; phytopharmaceuticals; immunosppressantsparticle size 1.8µm, 11% C
From CHF 729.00*

EC analytical columns NUCLEODUR® Sphinx RP, 5µm
distinct selectivity based on bifunctional surface coverage - USP L1 and USP L11pore size 110 Å, particle sizes 1,8µm, 3µm and 5µm; 14 %Chigh density of covalently bonded silanes for tailing-free peaks widens the scope for method developmentpH stability 1 - 10suitable for LC/MS due low bleeding characteristicshigh reproducibility and consistent quality due to tight QC proceduresrange of application: quinolone antibiotics, sulfonamides, xanthines, substituted aromaticsparticle size 5µm, 14% C
From CHF 582.40*

EC analytical columns NUCLEODUR® Sphinx RP, 3µm
distinct selectivity based on bifunctional surface coverage - USP L1 and USP L11pore size 110 Å, particle sizes 1,8µm, 3µm and 5µm; 14 %Chigh density of covalently bonded silanes for tailing-free peaks widens the scope for method developmentpH stability 1 - 10suitable for LC/MS due low bleeding characteristicshigh reproducibility and consistent quality due to tight QC proceduresrange of application: quinolone antibiotics, sulfonamides, xanthines, substituted aromaticsparticle size 3µm, 14% C
From CHF 729.00*

EC analytical columns NUCLEODUR® Sphinx RP, 1.8µm
distinct selectivity based on bifunctional surface coverage - USP L1 and USP L11pore size 110 Å, particle sizes 1,8µm, 3µm and 5µm; 14 %Chigh density of covalently bonded silanes for tailing-free peaks widens the scope for method developmentpH stability 1 - 10suitable for LC/MS due low bleeding characteristicshigh reproducibility and consistent quality due to tight QC proceduresrange of application: quinolone antibiotics, sulfonamides, xanthines, substituted aromaticsparticle size 1.8µm, 14% C
From CHF 729.00*

Guard columns for EC columns NUCLEODUR® C18 Isis, 3µm
C18 phase with special polymeric, crosslinked surface modification - USP L1pore size 110 Å, particle sizes 1,8µm, 3µm and 5µm; 20%Chigh steric selectivityoutstanding surface deactivationsuitable for LC/MS due low bleeding characteristicspH stability 1 - 10broad range of application: steroids, (o,p,m-) substituted aromatics, fat-soluble vitaminsGuard columns for EC columns require the guard column adapter EC (Cat. No. 7.081 898).
From CHF 241.30*