BOD measurement system OxiTop®-i IS 6 / 12 | Type: OxiTop®-i IS 12

Easy-to-use, respirometric measuring system for determining the biological oxygen demand (BOD). The method is based on changes of pressure in a closed system using measuring heads attached to the sample bottles. The BOD can be determined simultaneously in up to 6 or 12 samples.
  • No dilution of the sample required
  • Direct reading of the BOD, the time course and the intermediate values on the graphical display of the measuring heads
  • Input of the used sample volume directly at the measuring head
  • Monitoring time between 1 and 7 days
  • Permanent display of the current status at each measuring head
  • Coloured measuring heads with adjustable, numerical sample identification

Scope of supply: OxiTop®-i IS 6: 6 x measuring heads (3 x blue, 3 x grey), 6 x sample bottles PF600, 6 x rubber quivers, CO2 absorber, nitrification inhibitor, overflow measurement flasks, 6 x stirring rods, stirring rod remover, stirring platform SI 6
OxiTop®-i IS 12: 12 x measuring heads (6 x blue, 6 x grey), 12 x sample bottles PF600, 12 x rubber quivers, CO2 absorber, nitrification inhibitor, overflow measurement flasks, 12 x stirring rods, stirring rod remover, stirring platform SI 12

An incubator is required to operate the OxiTop®-i IS. Please order separately.

colorpickercolorpicker

Specifications
Pressure range:
500 ... 1250 hPa
BOD range:
0 ... 4000 mg/l
Display:
Graphical LCD, background-illuminated
Power supply of measuring heads: Power supply of stirring platform:
1 x CR 2450 100 ... 240 V, 50/60 Hz

Hazardous Substance Data
GHS
Signal word
Gefahr
H-Satz
H290, H314
P-Satz
P280, P301+P330+P331, P305+P351+P338
SDS
Link
Plug type: EU
Type: OxiTop®-i IS 12

Accessories

Xylem Analytics Germany (WTW)
Measuring heads OxiTop®-i
Menu-operated measuring heads. Output of the BOD measurement values directly on the display.3 operating buttonsBacklit graphic LCDControl LEDVolume pre-selectionMeasurement duration selectable (1 to 7 days)Display of measuring curveDisplay of current readings
From CHF 700.20*

Xylem Analytics Germany (WTW)
Stirring platforms OxiTop® for BOD measurement
These Stirring platforms have been specially developed for BOD measurement with the OxiTop® system. Software-controlled speed regulation prevents the magnetic stirrer bar from getting caught or wobbling. The speed is selected so that an optimal gas exchange with the sample takes place. The stirrer is maintenance-free and non-wearing as it contains no moving parts.The IS 6-Var model has been specially developed for use with large measuring vessels and has space for 6 measuring vessels. Its outer dimensions are identical to those of the IS 12.SpecificationsNumber of stirring positions:6 or 12Speed:180 to 450 rpm.Safety class:3, IEC 1010IP code:IP 30Power supply:100 ... 240 V, 50/60 Hz
From CHF 1,017.60*

Other customers also bought

Xylem Analytics Germany (WTW)
BOD Measuring system OxiTop®-IDS for determination of soil respiration
BOD measurement system for all types of respirometric measurements, e.g. soil respiration, microbiological activity measurement, biogas determination as well as extended BOD measurement for the industrial waste water plants and further degradation tests in 3 selectable measuring types, BOD standard, BOD special and pressure.With the proven Bluetooth® connectivity and the convenient operation via MultiLine® multi parameter instrument Multi 3620 IDS or Multi 3630 IDS. Using a Multi 3620 IDS or Multi 3630 IDS in BOD special mode the BOD measuring range extends to 400000 mg/l. For an already existing Multi 3620 or 3630 IDS, a firmware update is sufficient. Herewith beneath the OxiTop® applications also measurement of pH, conductivity, solved oxygen and turbidity are available. All heads can be used independently for routine BOD measurements from 1 to 7 days.Bluetooth®connectivityDirect calculation of all results in the meterRepresentation of curves for monitoringParallel measurement of different examinations and methodsExport to data acquisition programsRespirometric measuring system for 6 measuring heads for determination of aerobic soil respiration, OxiTop®-IDS B6M-2.5 acc. to AT4 guideline. These sets are suitable for forecast, survey and monitoring of clean-up operations as well as measurement of bio-degradation of pesticides, fungicides, insecticides and fertilizers for example.Scope of supply:OxiTop®-IDS B6: 6 measuring heads, 6 sample bottles PF45/500 (500 ml), 6 adapters OxiTop® AD/SKOxiTop®-IDS B6M: as OxiTop®-IDS B6, but with 6 vessels MG 1,0 (1000 ml)OxiTop®-IDS B6M-2.5: as OxiTop®-IDS B6M, but with 6 vessels MG 2,5 (2500 ml) and Soda-Lime CO2 absorbentPlease order CO2 absorber NHP 600 (9.303 403) separately.The IDS multi parameter measuring instruments Multi 3620 IDS Set WL or Multi 3630 IDS Set WL are required. Please order separately.SpecificationsPressure range:500 ... 1250 hPaBOD range:0 ... 4000 mg/lMeasurement period:0,5 h ... 180 dMemory:360 valuesDisplay:LCDPower supply:100 ... 240 VAC, 50/60 Hz
From CHF 6,927.80*

Xylem Analytics Germany (WTW)
BOD measuring system OxiTop®-IDS for determination of aerobic degradation
BOD measurement system for all types of respirometric measurements, e.g. soil respiration, microbiological activity measurement, biogas determination as well as extended BOD measurement for the industrial waste water plants and further degradation tests in 3 selectable measuring types, BOD standard, BOD special and pressure.With the proven Bluetooth® connectivity and the convenient operation via MultiLine® multi parameter instrument Multi 3620 IDS or Multi 3630 IDS. Using a Multi 3620 IDS or Multi 3630 IDS in BOD special mode the BOD measuring range extends to 400000 mg/l. For an already existing Multi 3620 or 3630 IDS, a firmware update is sufficient. Herewith beneath the OxiTop® applications also measurement of pH, conductivity, solved oxygen and turbidity are available. All heads can be used independently for routine BOD measurements from 1 to 7 days.Bluetooth®connectivityDirect calculation of all results in the meterRepresentation of curves for monitoringParallel measurement of different examinations and methodsExport to data acquisition programsThese tests quantify the biological degradability of chemicals. The OxiTop®-IDS A12 is also suited for high dilutions.Respirometric degradability tests according to OECD 301F/DIN EN ISO 9408Versatile measurement by using the BOD special modeScope of supply:OxiTop®-IDS Set 6: 6 x OxiTop®-IDS measuring heads, 6 x bottles PF600 (510 ml), 6 x rubber sleeves, nitrification inhibitor, overflow measuring flask , 6 x magnetic stirring bars, stirring bar retriever, stirring platform IS 6OxiTop®-IDS Set 12: 12 x OxiTop®-IDS measuring heads, 12 x bottles PF600 (510 ml), 12 x rubber sleeves, nitrification inhibitor, overflow measuring flask, 12 x magnetic stirring bars, stirring bar retriever, stirring platform IS 12Erweiterungssatz für OxiTop®-IDS 6/12: 6 resp.12 OxiTop®-IDS measuring heads, 6 resp.12 bottles, universal power adapter, 6 resp.12 rubber sleeves, 6 resp.12 magnetic stirring bars, stirring platform IS 6 resp. IS 12OxiTop®-IDS A6: 6 x OxiTop®-IDS measuring heads, 6 x bottles PF45/1000 (1000 ml), 6 x adapter OxiTop® AD/SK, nitrification inhibitor, 6 x magnetic stirring bars, stirring bar retriever, stirring platform IS 6-VarOxiTop®-IDS A12: 12 x OxiTop®-IDS measuring heads, 12 x bottles PF45/250 (250 ml), 12 x adapter OxiTop® AD/SK, nitrification inhibitor, 12 x magnetic stirring bars, stirring bar retriever, stirring platform IS 12Please order CO2 absorber NHP 600 (9.303 403) separately.The IDS multi parameter measuring instruments Multi 3620 IDS Set WL or Multi 3630 IDS Set WL are required. Please order separately.SpecificationsPressure range:500 ... 1250 hPaBOD range:0 ... 4000 mg/lMeasurement period:0,5 h ... 180 dMemory:360 valuesDisplay:LCDPower supply:100 ... 240 VAC, 50/60 Hz
From CHF 7,178.70*

Xylem Analytics Germany (WTW)
BOD Measuring system OxiTop®-IDS for determination of biogas/microbiology
BOD measurement system for all types of respirometric measurements, e.g. soil respiration, microbiological activity measurement, biogas determination as well as extended BOD measurement for the industrial waste water plants and further degradation tests in 3 selectable measuring types, BOD standard, BOD special and pressure.With the proven Bluetooth® connectivity and the convenient operation via MultiLine® multi parameter instrument Multi 3620 IDS or Multi 3630 IDS. Using a Multi 3620 IDS or Multi 3630 IDS in BOD special mode the BOD measuring range extends to 400000 mg/l. For an already existing Multi 3620 or 3630 IDS, a firmware update is sufficient. Herewith beneath the OxiTop® applications also measurement of pH, conductivity, solved oxygen and turbidity are available. All heads can be used independently for routine BOD measurements from 1 to 7 days.Bluetooth®connectivityDirect calculation of all results in the meterRepresentation of curves for monitoringParallel measurement of different examinations and methodsExport to data acquisition programsFor the measurement of anaerobic degradability with OxiTop®-IDS/B measuring heads. The main application for these sets is the testing of fermentability of biological waste for biogas plants acc. to VDI 4630. The yield of methane can be measured in the pressure mode.Convenient and safe operation within an extended pressure range of up to 1500 hPaPressure range excess warningCorrosion-proof head even in presence of H2SScope of supply:OxiTop®-IDS AN6: 6 x OxiTop®-IDS/B measuring heads, 6 sample bottles MF45/1000 (1000 ml), nitrification inhibitor, 6 x magnetic stirring bars, stirring bar retriever, 1 stirring platform IS 6-VarOxiTop®-IDS AN12: 12 x OxiTop®-IDS/B measuring heads, 12 sample bottles MF45/250 (250 ml), nitrification inhibitor, 12 x magnetic stirring bars, stirring bar retriever, 1 stirring platform IS-12Please order CO2 absorber NHP 600 (9.303 403) separately.The IDS multi parameter measuring instruments Multi 3620 IDS Set WL or Multi 3630 IDS Set WL are required. Please order separately.SpecificationsPressure range:500 ... 1250 hPaBOD range:0 ... 4000 mg/lMeasurement period:0,5 h ... 180 dMemory:360 valuesDisplay:LCDPower supply:100 ... 240 VAC, 50/60 Hz
From CHF 11,126.80*

Similar products

Dissolved oxygen bottles, Winkler pattern
Winkler pattern. Soda-lime glass.For determination of dissolved oxygen in water. The measured capacity is specified to ± 0,01ml. With white labelling area. Solid, bevelled glass stopper, secured with an accessory spring clip. Each bottle is adjusted to the relevant stopper. Stoppers and bottles are therefore not interchangeable. Each bottle and its stopper is marked with a unique, matching identification number.
From CHF 33.90*

Thermostatic cabinets
The incubators from Lovibond® are designed for continuous tempering for different applications, mainly for the determination of BOD, the storage of wastewater samples, and the determination of enzymatic activity. The temperature range is +2°C up to +40°C and can be regulated in steps of 0,1°C. Temperature tolerance is defined with +/- 1°C respectively +/- 0,5°C (at 20°C). Low engergy consumption due to reinforced isolation. The interior of the cabinets is equipped with sockets for connecting stirrers. Illuminated LED display with actual / setpoint display.Temperature range 2 °C to 40 °C, continuously adjustable in steps of 0.1 °CLow power consumptionIlluminated LED display of preset and current temperaturesIdeal for BOD determination at 20 °CPower sockets inside the incubatorStandard door or glass doorSpecificationsCoolant:R134aFan:Axial, delivery rate 320m3/hPower supply:220-230V/50Hz* With glass door
From CHF 2,035.00*

Overflow Measuring Flask for OxiTop®
Glass measuring flask with fixed volume doses for the easy and accurate measurement of the required sample volume for respirometric BSB measurements.
From CHF 66.20*

Controlled Temperature Cabinets BOD
Compact temperature cabinets with internal plugs for the use of OxiTop® IS 12 stirring platforms. Models with insulation glass door allow for visual control of the OxiTop® heads without opening the door.Incubation conforming to standardsSuited for BOD, OECD 301F, soil respiration, anaerobic degradationTemperature adjustable in steps of 1 K between 10 and 40 °CEco-friendly refrigerant R600aNote: The necessary temperature constancy will only achieved in combination with the samples.TS 608/2i: Model for standard applications, with 2 internal plugs, incl. 2 shelvesTS 608-G/2i: As TS 608/2i, but with door made of insulation glassSpecificationsTemperature range:10 ... 40 °CIncrement:1 KTemperature stability:±0,5 K
From CHF 4,055.00*

Xylem Analytics Germany (WTW)
Measuring heads OxiTop®-i
Menu-operated measuring heads. Output of the BOD measurement values directly on the display.3 operating buttonsBacklit graphic LCDControl LEDVolume pre-selectionMeasurement duration selectable (1 to 7 days)Display of measuring curveDisplay of current readings
From CHF 700.20*

BOD sensor system
Measuring systems for the reliable determination of 90 to 999 ppm BOD. Complete with sensor heads and multi-position magnetic stirrer.The sensor heads are screwed directly onto the BOD bottlesAutomatic storage of 5 results in 24-hour intervalsMeasured readings in mg/l (ppm) can be read directly on the sensor at any timeProtected against splashing water (IP 54)Scope of supply BOD sensor system 6: 6-position magnetic stirrer, each 6 BOD sensors incl. batteries, 500 ml brown glass bottles, KOH reservoirs and magnetic stirring rodsScope of supply BOD sensor system 10: 10-position magnetic stirrer, each 10 BOD sensors incl. batteries, 500 ml brown glass bottles, KOH reservoirs and magnetic stirring rodsSpecificationsBOD range:90 ... 999 ppmDisplay:LED (3 digits)IP code:IP 54
From CHF 272.00*

Adapter AD/SK for BOD measuring system OxiTop®
For OxiTop® measuring heads, for all sample and measuring bottles series PF45/.. and MF45/.., autoclavable (121 °C). Incl. OxiTop® AD adapter, OxiTop® SK screwable adapter, DI45 gasket for adapter VS45.
From CHF 140.30*