Mini-Diaphragm vacuum pumps LABOPORT® N 96, chemically-resistant | Type: N 96

The Pump combines a high flow rate with a very compact design. Suitable for filtration, SPE, and liquid aspiration using a vacuum. Due to the manual rotational speed control, the pump is quiet, very energy efficient, and can be optimally adjusted in accordance with the application.
  • Easy-to-clean surface
  • Very small footprint
  • Adjustable in flowrate due to manual rotational speed control
  • PTFE-coated diaphragm for use with aggressive/corrosive gases and vapors


Specifications
Ultimate vacuum (abs.): Operating pressure:
130 mbar 2.5 bar
Connectors for tube:
ID 6 mm
Permissible ambient temperature:
5 ... 40 °C
Pump head:
PPS
Diaphragm:
PTFE coated
Valves:
FKM
Depth mm: 156
Flow rate l / min.: 7
Height mm: 119
Plug type: EU, UK, CH
Type: N 96
Type of auxiliary energy: 100 ... 240 V, 50/60 Hz
Ultimate vacuum mbar (abs).: 130
Weight kg: 1.3
Width mm: 75

Other customers also bought

KNF NEUBERGER GmbH
Diaphragm vacuum pumps LABOPORT® N 820 G / N 840 G, chemically-resistant
The compact pumps feature a control knob for manual adjustments of the flow rate, making them well suited to a wide variety of applications, e.g. rotary evaporation, distillation, gel drying, degassing as well as the use with vacuum ovens and vacuum concentrators. Due to the manual rotational speed control, the pumps are quiet, very energy efficient, and can be optimally adjusted in accordance with the application.Easy-to-clean surfaceAdjustable in flow rate due to manual rotational speed controlCombination of PTFE pump head and PTFE-coated diaphragm makes the pump ideal for extremely aggressive/corrosive gases and vaporsHigh level of compatibility with vapor and condensationIntegrated gas ballast valve3-color status display: In operation / Stand-by / ErrorATEX-compliant in accordance with II 2/-G IIB+H2 T3 internal atmpsphere only100% oil-free transfer to ensure uncontaminated transfer, evacuation and compressionOptional: Easily expandable with separators and/or condensersSpecificationsUltimate vacuum (abs.): Operating pressure:6 mbar 0.1 barConnectors for tube:ID 9/10 mmPermissible ambient temperature:5 ... 40 °CPump head:TFM™ PTFEDiaphragm:PTFE-beschichtetValves:FFPM
From CHF 2,218.70*

Similar products

Mini Diaphragm Vacuum Pumps LABOPORT®
For Filtration, SPE, Degassing, Fluid aspiration.N 938.50 KT.18 ensures exceptionally fast evacuation by the parallel and in series connection of both pump headsPTFE-coated diaphragm is ideal for aggressive/corrosive gases and vaporsPump head made from PPS (Polyphenylsulfide), valves made from FFPM (Perfluoro rubber)SpecificationsConnectors for tube: N 816.3 KT.18 / N 816.1.2 KT.18: N 938.50 KT.18:ID6 mm ID10 mmPermissible media and ambient temperature:5 to 40 °CFlow rate:Up to 1.8 m³/hUltimate vacuum:Up to 15 mbar abs.IP code:IP 20
From CHF 1,038.50*

Diaphragm vacuum pumps LABOPORT®
Application: Fluid aspiration, Degassing, Gel drying, Rotary evaporation, Centrifugal concentration, DistillationFlow rate up to 2.04 m³/h / Ultimate vacuum up to 8 mbar abs.High level of vapor and condensate compatibilityPTFE pump head combined with PTFE-coated diaphragm are ideal for extremely aggressive/corrosive gases and vaporsN 820.3 FT.18 and N 840.3 FT.18: ATEX-compliant in accordance with ATEX II 2/-G IIB+H2 T3 Gb internal atmosphere onlySpecificationsOperating pressure:1 barConnectors for tube:ID10 mmPermissible media and ambient temperature:5 to 40 °CPump head:PTFEDiaphragm:PTFE-coatedValves:FFPM
From CHF 2,001.30*

Diaphragm pumps, Aluminium
Improved performance, increased pumping speed (up to 16 m³/h) and better ultimate vacuum (up to 0.3 mbar). Extend applications with non-aggressive gases whether used in the laboratory or for industrial processesVery low leak rate due to enhanced leak-tight tubing connections, resulting in consistent performance characteristics - even after many years of operation. Ideal for analytical applicationsLong diaphragm and valve lifetimes: made of highly flexible FPM, with fabric-reinforced double diaphragms for improved long term stabilityVery quiet and ultra low vibration due to compact drive with patented motor drive system. Ideal as a built-in component for sensitive analytical equipmentEasy to clean due to smooth surfaces. A robust solution for numerous applications in industrial environmentsThe VARIO® design provides vacuum control by precise and continuous adaption of the diaphragm pumps motor speed, and includes the vacuum pump, as well as the VACUU·SELECT controller.Country-specific power cord versions available on request.SpecificationsVacuum inletTubing nozzle DN 8-10 mm:ME 4 NT, ME 4R NT, ME 8 NT, MZ 2 NT, ME 2 NTKF DN 16:MZ 2D NT, MD 4 NT, MV 2 NT, MD 4 VARIO select, MD 2 VARIO selectPressure outletSilencer / G1/4":MZ 2 NT, MZ 2D NT, MD 4 NT, MV 2 NT, ME 2 NT, MD 4 VARIO select, MV 2 VARIO selectTwin silencers / G1/4":ME 8 NT, ME 4 NTTubing nozzle DN 8-10 mm:ME 4R NTKF DN 25:MD 12 NT, MV 10 NT, ME 16 NT, MD 12 NT VARIO select, MV 10 NT VARIO selectSilencer / G1/2":MD 12 NT, MV 10 NT, ME 16 NT, MD 12 NT VARIO select, MV 10 NT VARIO select
From CHF 1,460.00*

Chemistry Diaphragm Vacuum Pumps with ATEX compliance
ATEX chemistry diaphragm pumps offer all advantages of oil-free chemistry diaphragm pumps. Typical applications are rotary evaporators and drying ovens with potentially explosive atmospheres. The ATEX approval includes the interior of the pump (in contact with pumped gases) as well as the surrounding area of the pump.Outstanding chemical resistance and superior vapor toleranceMainly made of antistatic materialsFlame proof motor with integrated, self-locking overload and excess temperature protection for direct 230V / 50Hz single phase power supplyOverpressure safety relief valves internally and at outletWith separate gas ballast connection part for use of inert gasSafety diaphragm technology with option for inert gas purge and detection of diaphragm breakageATEX compliance:Pump chamber (pumped gases): II 2G IIC T3 XExterior space (pump environment): II 2G IIB T4 X (with inert gas purging) / II 3G IIB T4 X (without inert gas purging)Speed-controlled ATEX VARIO vacuum pumps on request.SpecificationsMZ 2C EXVacuum inlet:Small flange KF DN 16Pressure outlet:Small flange KF DN 16MV 10C EX / MD 4C EXVacuum inlet:Small flange KF DN 25Pressure outlet:Kleinflansch KF DN 16MZ 2C EX+AK+EK / MD 4C EX+AK+EKVacuum inlet:Small flange KF DN 16Pressure outlet:Tubing nozzle DN 8-10 mmCooling water connection:2 x tubing nozzle DN 6-8 mm
From CHF 7,240.00*

Diaphragm vacuum pumps -NT Series, Chemistry design
Improved performance, increased pumping speed and lower ultimate vacuum extends applications in both the laboratory and in industrial applicationsLong-life diaphragm with PTFE sandwich construction and unstressed diaphragm supportEasy service/exchange of diaphragm or valves due to novel integrated valve head assembly. Easy dismantling, cleaning and reassembly without requiring readjustmentVery quiet and ultra low vibration due to compact drive with patented motor control system. Ideal as a built-in component for sensitive equipment in both the laboratory and in industrySuperior vapour tolerance due to integral tubing connections and gas ballast valve for continuous purge (for ME 16C NT, MZ 2C NT, MD 4C / 12C NT and MV 10C NT)Easy to clean due to smooth exterior surfacesThe VARIO® design provides vacuum control by precise and continuous adaption of the chemistry diaphragm pumps motor speed, and includes the vacuum pump, as well as the VACUU·SELECT controller.Diaphragm pump MD 4CRL NT with reduced leakage rate (0.001 mbar x l/s).Country-specific power cord versions available on request.
From CHF 2,060.00*

Diaphragm pumps chemistry design, ME 1C, MZ 1C, MD 1C
The diaphragm pumps ME 1C offer a compact and high performance solution. With their easy-to-use functionality, they are the perfect partner for both single and multiple filtrations.One-stage diaphragm pumps are an excellent solution for continuous, oil-free pumping of gases and vapors for modest vacuum requirements. In contrast to water-jet pumps, they do not consume water and therefore do not produce any contaminated waste water in daily use.Vacuum filtration is frequently used for sample preparation in chemistry, microbiology, waste water control and analysis.In the chemistry diaphragm pumps ("C") all major parts in contact with pumped media are made of chemically resistant fluoroplastics. The ME 1C is also often used for solid phase extraction (SPE).An optional manual regulator valve with dial gauge enables variable fine adjustment of the pumping speed and the ultimate vacuum.Gas ballast for reliable pump performance.Two up to four stage chemistry diaphragm pumps (letters in the product name Z, D or V) are equipped with a manual gas ballast valve as standard. The supply of gas ballast minimizes the risk of condensation inside the pump.Diaphragm pumps ATEX-models available on request. Country-specific power cord versions available on request.
From CHF 1,270.00*

Spare parts sets for KNF Pumps
For the maintenance of KNF pumps. Contains all necessary membranes, seals, etc.
From CHF 51.82*