Nitrogen generators Precision Nitrogen | Type: Precision Nitrogen 1000

Nitrogen generators for the GC. For safe and continuous production of nitrogen with a purity of 99.9995%.
  • On-demand generation of nitrogen as purge gas and for sample preparation in standard analyses
  • Compact, modular and stackable system
  • Constant and uniform supply for reliable and reproducible analyses
  • Can be individually combined with PEAK hydrogen and zero air generators
  • No contamination of the system
  • Very fast start time and rapid achievement of the required operating purity
  • Available with different flow rates
  • Generator for headspace requirements available, compatible with most headspace samplers
  • Very low maintenance requirements

Scope of supply: Nitrogen generator, 1 m PTFE tubing, 1/4" compression fitting, 1/8" compression fitting, mains power cable for EU, UK and US


Specifications
Purity:
99.9995 %
Gas connection:
1/4"
Permissible ambient temperature:
5 ... 35 °C
Dimensions (W x D x H):
380 x 540 x 256 mm
Power supply:
110/230 V, 50/60 Hz
Warranty:
1 year
Flow rate L / min.: 1.00
Pressure max. bar: 5.5 (80 psi)
Type: Precision Nitrogen 1000
Weight kg: 26

Similar products

Accessories for Precision hydrogen generators
For Precision Hydrogen and Precision Hydrogen trace models.
From CHF 310.97*

Gas filters
Gas filters are an essential part of GC analysis as contaminants in gases can significantly impact the quality of results. Oxygen, hydrocarbons and moisture can lead to problems such as noisy baselines, moisture entering the GC column and excessive bleed. The gas filter kit consists of a gas filter and a connection unit.Fast stabilization timesThe gas filter system consists of two key parts: the filters and the connecting unitThe connecting unit has inlet and outlet connectors for the gas linesThe connecting unit can be bench or wall-mountedCan be used in combination with other filtersIndicator color change tells you when to change your filter
From CHF 324.38*

Accessories for gas chromatography flow meters GF500/GF1000
Adapters for detectors and other accessories.
From CHF 151.00*

Gas chromatography flow meter GF1000
Very robust, portable device for measuring the flow rate of gas chromatographs and for calibrating air sampling canisters. Measurement is performed in real time, allowing simultaneous flow and pressure measurement to improve validation efficiency. Reduces downtime.For real-time measurement of more than 30 common gases over a wide rangeCheck the volume flow, mass flow, pressure and temperature at the inlet and detector outlet of the GCFlow calibration with NIST-traceable accuracyImmediately ready for use after switching on, measurement completed within 20 secondsFast response time of 10 msTFT displayRS232 interface for data transfer18 hours battery lifeScope of supply: GC flow meter, hard-shell carrying case, spare tubings, tubing connector fittings, power supply with adapters for EU, UK, CH and USSpecificationsRange:0.1 ... 1000 ml/minAccuracy:±0.8 % of reading, 0.2 % of full scaleResolution: Turn-down Ratio:0.1 ml/min 200:1Operating temperature:-10 ... 60 °CInlet pressure:max. 1000 kPa (145 psi)Dimensions:60 x 170 x 24 mmWeight:450 g
From CHF 4,196.20*

Preventative Maintenance
* 20H Continuous operation approx 6 to 7 months* 40H Continuous operation approx 4 to 5 months* 60H Continuous operation approx 2 to 3 months
From CHF 336.05*

Gas chromatography flow meter GF500
Convenient digital flow meter for the simple, accurate and repeatable measurement of flow in gas chromatographs. User friendly, handy design. Can be used with the carrier gases Air, Hydrogen, Nitrogen, Helium, Carbon dioxide, Argon and Argon/Methane. OLED display shows flow rate and further information. With pressure and temperature compensation. Suitable for columns with diameters of 100, 180, 200, 250, 320, 450, 530 and 750 µm.Measurement of flow rate, linear velocity and split ratioHigh resolution25 point calibration, traceable to National StandardsRechargeable batteryAuto power offScope of supply: Flow meter with case, tubings, tubing adapter fittings, tubing clips, tie-wraps, universal charger with USB connector, operation manual, calibration certificate.Please order adapters for direct connection to the detector separately.SpecificationsRange:0…500 ml/min. (0…300 ml CO2)Accuracy:0.4 ml/min. / ±2.5 %Resolution:0.1 ml/min.Operating temperature:15…35 °C, calibrated at 21±2 °CInlet pressure:max. 175 kPaDimensions:68 x 30 x 130 mmWeight:150 g
From CHF 1,250.00*

Hydrogen generators Precision Hydrogen
For the safe and continuous production of hydrogen with a purity of 99.9995% for GC and GC/MS.On-demand generation of high-purity hydrogen as detector gas for the FIDCompact, modular and stackable systemHydrogen production from deionised water using proton exchange membraneInternal leakage detection with automatic switch-off functionMinimal hydrogen storage in the systemFront LED touch screen with status displayCan be individually combined with PEAK zero nitrogen and zero air systemsSystems are available with different flow ratesVery low maintenance requirements3 years warranty on the hydrogen cellScope of supply: Hydrogen generator, 1 m Tygon® tubing, Deioniser column refill, barbed hose fitting, mains power cable for EU, UK and US, 2 x transit plugsSpecificationsPurity:99.9995 %Max. pressure:6.9 bar/100 psiRequired water quality:1.0 µS/cmGas connection:1/8" SwagelokPermissible ambient temperature:10 ... 35 °CDimensions (W x D x H):380 x 540 x 406 mmPower supply:110/230 V, 50/60 HzWarranty:3 years (cell) / 1 year (device)
From CHF 16,600.00*

Gas filters big trap
Gas filters are an essential part of your GC analysis as contaminants in gases can significantly impact the quality of results. Oxygen, hydrocarbons and moisture can lead to problems such as noisy baselines, moisture entering the GC column and excessive bleed.Heavy-walled aluminium tubeHigh capacity filtersSintered stainless steel frits prevent particulate contaminationSpecificationsVolume:750 cm3Pessure rating:up to 17.2 bar
From CHF 663.82*