Spectrophotometers XD 7000 VIS and XD 7500 UV-VIS | Type: XD 7000 VIS

UV-VIS and VIS spectrophotometers with dual beam optics. The instruments benefit from a barcode test recognition system, over 150 pre-programmed analytical methods and automatic cuvette detection. Analytical quality assurance procedures include checks of the photometer, the total system (including methods) and sample matrix effects. Further functions of the spectrophotometers include measurement of transmission and absorbance, scanning of spectra, kinetics analysis and creation of user-defined methods.
  • Premium optical system with reference beam
  • Automatic test recognition with internal barcode reader
  • Supports round cuvettes with 13, 16, 24 mm and rectangular cuvettes with 10, 20, 50 mm
  • Automatic cuvette type detection
  • More than 150 analytical methods implemented
  • 7'' colour display and keypad
  • Ethernet, USB
  • 20 user profiles possible
  • Up to 1000 user programmes
  • Creation of up to 100 further user-defined methods
  • Password protection possible


Specifications
XD 7000 VIS // XD 7500 UV-VIS
Optical System:
grid monochromator with reference beam
Wavelength range:
320 - 1100 nm // 190 - 1100 nm
Bandwidth:
4 nm
Wavelength accuracy:
±1 nm on all Holmium peaks
Wavelength repeatability:
better than 0.5 nm
Photometric range:
-3.3 to +3.3 Abs
Photometrical resolution / Transmission:
0.001 Abs / 0.1%
Photometric accuracy / repeatability:
0.003 Abs below 0.6 Abs 0.5 % from 0.6 to 2.0 Abs
Photometrical linearity:
1% up to 2.0 Abs between 340 to 900 nm
Drift:
0.005 Abs per hour after 15 minutes heat up time
Internal Storage:
40 MB for approx. 5000 data sets
Lamps:
Tungsten-halogen-lamp // Xenon flash lamp
Dimension (W x D x H): Weight:
422 x 323 x 195 mm approx. 4.5 kg
Power supply: Protection class:
100 - 240V, 50/60 Hz IP 30
Plug type: EU/UK/US
Type: XD 7000 VIS

Accessories

Tintometer GmbH
Cuvettes for photometers
From CHF 5.20*

Tintometer GmbH
Accessories for Lovibond® photometers
From CHF 4.10*

Similar products

Tube tests NANOCOLOR® Sulfide / Sulfite / Sulfate
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 103.00*

Tube tests NANOCOLOR® ortho- and total Phosphate
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 128.22*

Tintometer GmbH
Accessories for Lovibond® photometers
From CHF 4.10*

Tube tests NANOCOLOR® COD
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.DIN ISO 15705
From CHF 113.40*

Photometers MD 100
The Lovibond® MD 100 Photometers are designed for analysis of different parameters in drinking water, industrial process water and waste water. With a total of more than 30 different types, instruments are available for routine testing as well as for special applications. The MD 100 uses high quality interference filters with long-life LEDs as a light source without any moving parts in a transparent sample chamber. The units supply accurate, reproducible results very quickly. Other major advantages include ease of operation, ergonomic design, compact dimensions and safe handling. Provided with calibration and software-based adjustment options the MD 100 is suitable for use as a testing instrument. The tests are conducted using either Lovibond® tablet reagents with long-term stability and a shelf life of 5 or 10 years, VARIO powder reagents or using liquid reagents.Optics: High-quality Interference FiltersWavelength accuracy: ±1 nm.Power supply: 4 micro batteries (AAA), capacity approx. 17 hours or 5000 tests.Automatic switch-off.LCD Display (backlit on keypress).Internal ring memory for 16 data sets.Dimensions (L x W x H): 155 x 75 x 35 mm.Scope of supply: Photometer in a plastic carrying case, with reagents for 100 tests, cells, batteries and standard accessories.Optional: IRiM - infrared interface module for data transfer to computer or printer.*Delivery without reagents for measuring range 0.1 - 10 mg/l Cl2.**24mm diam. glass cell***10mm diam. multi cell-2
Price on request

Waste Water Set-Up MD 610
Flexible wastewater measuring station with mobile photometer MD 610 and thermoreactor RD 125, complete with reagents for COD measurement and the appropriate accessories. With the MD 610, the measurement results of the wastewater can be called up and evaluated on a smartphone or tablet. The RD 125 thermoreactor is equipped with 24 holes for 16 mm cuvettes.Data transfer via Bluetooth® and AquaLX® appInterference filter for increased reproducibility of the resultsMemory for 500 measurement results120 pre-programmed methodsScope of supply: Photometer MD 610, standard accessories, Thermoreactor RD 125, Cuvette tests: COD (0 ... 150 mg/l, 0 ... 1500 mg/l, ammonium VARIO HR (1 ... 50 mg/l N), nitrate VARIO (1 ... 30 mg/l N), nitrite LR VARIO Powder Pack (0.01 ... 0.3 mg/l N), nitrogen VARIO Total HR (5 ... 150 mg/l N ), phosphate VARIO Total HR (0.02 ... 1 mg/l P / 0.06 ... 3.5 mg/l PO4), cuvette stand, membrane filtration set, operating instructions, warranty declaration
Price on request

Photometers MD 110
Photometer for the analysis of determined parameters in drinking, industrial and waste water. Different models are available for common analyses as well as for special applications.Ergonomic, waterproof designAccurate, reproducible measurement resultsUser calibration and single point calibrationMeasurement results are displayed directly in ABS or %TZero value remains valid for all tests with the same sample thanks to the one-time zero (OTZ) functionAutomatic storage of measured values with time and date stamp and optional data transfer (IRiM module)Bluetooth® interfaceScroll memoryAutomatic shutdownAdjustment function displayScope of supply: Photometer, carrying case, reagents for 100 tests, cuvettes, batteries, standard accessoriesFurther photometers available on request.SpecificationsOptics:Highly precise interference filters, LEDWavelengths:530 / 560 / 610 / 430 / 580 / 660 nmWavelength accuracy:±1 nmPhotometric range: pH:0.005 A 6,5 - 8,4Data memory:16 measurementsDimensions (W x D x H):75 x 155 x 35 mmWeight:260 gPower supply:4 x AAA micro batteriesIP code:IP 68
Price on request

Photometers MD 200
Benchtop devices suitable for mobile use. For precise water control through high-precision optics and high-quality interference filters with long-term stable LEDs as light sources.Automatic shutdownReal time clock and dateAdjustment function displayIlluminated LCD-displayFurther photometer versions available on request.SpecificationsMeasurement cycle:approx. 3 seconds (method dependent)Optics:Temperature compensated LED and photosensor intensifier in a waterproof sample chamberKeyboard:4-key polycarbonate film, splashproofDimensions (W x D x H):110 x 190 x 55 mmWeight:455 gPower supply:4 x AAIP code:IP 68pH:6.5 - 8.4
Price on request