BOD Measuring system OxiTop®-IDS for determination of soil respiration | Type: OxiTop®-IDS B6M-2.5

BOD measurement system for all types of respirometric measurements, e.g. soil respiration, microbiological activity measurement, biogas determination as well as extended BOD measurement for the industrial waste water plants and further degradation tests in 3 selectable measuring types, BOD standard, BOD special and pressure.
With the proven Bluetooth® connectivity and the convenient operation via MultiLine® multi parameter instrument Multi 3620 IDS or Multi 3630 IDS. Using a Multi 3620 IDS or Multi 3630 IDS in BOD special mode the BOD measuring range extends to 400000 mg/l. For an already existing Multi 3620 or 3630 IDS, a firmware update is sufficient. Herewith beneath the OxiTop® applications also measurement of pH, conductivity, solved oxygen and turbidity are available. All heads can be used independently for routine BOD measurements from 1 to 7 days.
  • Bluetooth®connectivity
  • Direct calculation of all results in the meter
  • Representation of curves for monitoring
  • Parallel measurement of different examinations and methods
  • Export to data acquisition programs

Respirometric measuring system for 6 measuring heads for determination of aerobic soil respiration, OxiTop®-IDS B6M-2.5 acc. to AT4 guideline. These sets are suitable for forecast, survey and monitoring of clean-up operations as well as measurement of bio-degradation of pesticides, fungicides, insecticides and fertilizers for example.

Scope of supply:
OxiTop®-IDS B6: 6 measuring heads, 6 sample bottles PF45/500 (500 ml), 6 adapters OxiTop® AD/SK
OxiTop®-IDS B6M: as OxiTop®-IDS B6, but with 6 vessels MG 1,0 (1000 ml)
OxiTop®-IDS B6M-2.5: as OxiTop®-IDS B6M, but with 6 vessels MG 2,5 (2500 ml) and Soda-Lime CO2 absorbent

Please order CO2 absorber NHP 600 (9.303 403) separately.
The IDS multi parameter measuring instruments Multi 3620 IDS Set WL or Multi 3630 IDS Set WL are required. Please order separately.

colorpicker

Specifications
Pressure range:
500 ... 1250 hPa
BOD range:
0 ... 4000 mg/l
Measurement period:
0,5 h ... 180 d
Memory:
360 values
Display:
LCD
Power supply:
100 ... 240 VAC, 50/60 Hz
Manufacturer Article Number: 209732
Type: OxiTop®-IDS B6M-2.5

Other customers also bought

Xylem Analytics Germany (WTW)
BOD Measuring system OxiTop®-IDS for determination of biogas/microbiology
BOD measurement system for all types of respirometric measurements, e.g. soil respiration, microbiological activity measurement, biogas determination as well as extended BOD measurement for the industrial waste water plants and further degradation tests in 3 selectable measuring types, BOD standard, BOD special and pressure.With the proven Bluetooth® connectivity and the convenient operation via MultiLine® multi parameter instrument Multi 3620 IDS or Multi 3630 IDS. Using a Multi 3620 IDS or Multi 3630 IDS in BOD special mode the BOD measuring range extends to 400000 mg/l. For an already existing Multi 3620 or 3630 IDS, a firmware update is sufficient. Herewith beneath the OxiTop® applications also measurement of pH, conductivity, solved oxygen and turbidity are available. All heads can be used independently for routine BOD measurements from 1 to 7 days.Bluetooth®connectivityDirect calculation of all results in the meterRepresentation of curves for monitoringParallel measurement of different examinations and methodsExport to data acquisition programsFor the measurement of anaerobic degradability with OxiTop®-IDS/B measuring heads. The main application for these sets is the testing of fermentability of biological waste for biogas plants acc. to VDI 4630. The yield of methane can be measured in the pressure mode.Convenient and safe operation within an extended pressure range of up to 1500 hPaPressure range excess warningCorrosion-proof head even in presence of H2SScope of supply:OxiTop®-IDS AN6: 6 x OxiTop®-IDS/B measuring heads, 6 sample bottles MF45/1000 (1000 ml), nitrification inhibitor, 6 x magnetic stirring bars, stirring bar retriever, 1 stirring platform IS 6-VarOxiTop®-IDS AN12: 12 x OxiTop®-IDS/B measuring heads, 12 sample bottles MF45/250 (250 ml), nitrification inhibitor, 12 x magnetic stirring bars, stirring bar retriever, 1 stirring platform IS-12Please order CO2 absorber NHP 600 (9.303 403) separately.The IDS multi parameter measuring instruments Multi 3620 IDS Set WL or Multi 3630 IDS Set WL are required. Please order separately.SpecificationsPressure range:500 ... 1250 hPaBOD range:0 ... 4000 mg/lMeasurement period:0,5 h ... 180 dMemory:360 valuesDisplay:LCDPower supply:100 ... 240 VAC, 50/60 Hz
From CHF 11,126.80*

Xylem Analytics Germany (WTW)
BOD measuring system OxiTop®-IDS for determination of aerobic degradation
BOD measurement system for all types of respirometric measurements, e.g. soil respiration, microbiological activity measurement, biogas determination as well as extended BOD measurement for the industrial waste water plants and further degradation tests in 3 selectable measuring types, BOD standard, BOD special and pressure.With the proven Bluetooth® connectivity and the convenient operation via MultiLine® multi parameter instrument Multi 3620 IDS or Multi 3630 IDS. Using a Multi 3620 IDS or Multi 3630 IDS in BOD special mode the BOD measuring range extends to 400000 mg/l. For an already existing Multi 3620 or 3630 IDS, a firmware update is sufficient. Herewith beneath the OxiTop® applications also measurement of pH, conductivity, solved oxygen and turbidity are available. All heads can be used independently for routine BOD measurements from 1 to 7 days.Bluetooth®connectivityDirect calculation of all results in the meterRepresentation of curves for monitoringParallel measurement of different examinations and methodsExport to data acquisition programsThese tests quantify the biological degradability of chemicals. The OxiTop®-IDS A12 is also suited for high dilutions.Respirometric degradability tests according to OECD 301F/DIN EN ISO 9408Versatile measurement by using the BOD special modeScope of supply:OxiTop®-IDS Set 6: 6 x OxiTop®-IDS measuring heads, 6 x bottles PF600 (510 ml), 6 x rubber sleeves, nitrification inhibitor, overflow measuring flask , 6 x magnetic stirring bars, stirring bar retriever, stirring platform IS 6OxiTop®-IDS Set 12: 12 x OxiTop®-IDS measuring heads, 12 x bottles PF600 (510 ml), 12 x rubber sleeves, nitrification inhibitor, overflow measuring flask, 12 x magnetic stirring bars, stirring bar retriever, stirring platform IS 12Erweiterungssatz für OxiTop®-IDS 6/12: 6 resp.12 OxiTop®-IDS measuring heads, 6 resp.12 bottles, universal power adapter, 6 resp.12 rubber sleeves, 6 resp.12 magnetic stirring bars, stirring platform IS 6 resp. IS 12OxiTop®-IDS A6: 6 x OxiTop®-IDS measuring heads, 6 x bottles PF45/1000 (1000 ml), 6 x adapter OxiTop® AD/SK, nitrification inhibitor, 6 x magnetic stirring bars, stirring bar retriever, stirring platform IS 6-VarOxiTop®-IDS A12: 12 x OxiTop®-IDS measuring heads, 12 x bottles PF45/250 (250 ml), 12 x adapter OxiTop® AD/SK, nitrification inhibitor, 12 x magnetic stirring bars, stirring bar retriever, stirring platform IS 12Please order CO2 absorber NHP 600 (9.303 403) separately.The IDS multi parameter measuring instruments Multi 3620 IDS Set WL or Multi 3630 IDS Set WL are required. Please order separately.SpecificationsPressure range:500 ... 1250 hPaBOD range:0 ... 4000 mg/lMeasurement period:0,5 h ... 180 dMemory:360 valuesDisplay:LCDPower supply:100 ... 240 VAC, 50/60 Hz
From CHF 7,178.70*

Xylem Analytics Germany (WTW)
BOD measurement system OxiTop®-i IS 6 / 12
Easy-to-use, respirometric measuring system for determining the biological oxygen demand (BOD). The method is based on changes of pressure in a closed system using measuring heads attached to the sample bottles. The BOD can be determined simultaneously in up to 6 or 12 samples.No dilution of the sample requiredDirect reading of the BOD, the time course and the intermediate values on the graphical display of the measuring headsInput of the used sample volume directly at the measuring headMonitoring time between 1 and 7 daysPermanent display of the current status at each measuring headColoured measuring heads with adjustable, numerical sample identificationScope of supply: OxiTop®-i IS 6: 6 x measuring heads (3 x blue, 3 x grey), 6 x sample bottles PF600, 6 x rubber quivers, overflow measurement flasks, 6 x stirring rods, stirring rod remover, stirring platform SI 6OxiTop®-i IS 12: 12 x measuring heads (6 x blue, 6 x grey), 12 x sample bottles PF600, 12 x rubber quivers, overflow measurement flasks, 12 x stirring rods, stirring rod remover, stirring platform SI 12An incubator is required to operate the OxiTop®-i IS. Please order separately.SpecificationsPressure range:500 ... 1250 hPaBOD range:0 ... 4000 mg/lDisplay:Graphical LCD, background-illuminatedPower supply of measuring heads: Power supply of stirring platform:1 x CR 2450 100 ... 240 V, 50/60 Hz
From CHF 5,669.20*

Accessories

Xylem Analytics Germany (WTW)
Measuring bottles for BOD measurement system OxiTop®
Iincl. 2 x nozzles, 2 x VS25 screwing sets for nozzle, 1 x GK 600 rubber sleeve, 2 x SEP25 septum for nozzle, 2 x STH25 support for nozzle
From CHF 335.90*

Xylem Analytics Germany (WTW)
Measuring vessels for BOD measuring system OxiTop®
Incl. 1 x DV/MG lid adapter with rack, gasket, 2 x GK 600 rubber sleeves, 4 x DV/MG/KL clamps, 1 x MB 50 measuring beaker (50 ml)
From CHF 346.80*

Xylem Analytics Germany (WTW)
Wireless measuring heads OxiTop® IDS
OxiTop®-IDS wireless measuring head with Bluetooth® LE technology for operation with Multi 3620 IDS or Multi 3630 IDS. For routine BOD readings also operable without IDS multiparameter instrument. OxiTop®-IDS/B with enhanced pressure range up to 1.5 bar and H2S resistant pressure sensor for biogas measurement.Memory for 360 measuring points3 operating buttonsBacklit graphic LCDControl LEDVolume pre-selectionFor routine BOD readings measurement duration selectable (1 to 7 days)Display of measuring curveDisplay of current readingsIntermediate values available
From CHF 935.80*

Xylem Analytics Germany (WTW)
Sample bottles for BOD measurement system OxiTop®
From CHF 30.30*

Xylem Analytics Germany (WTW)
Wireless module for WTW® measuring instruments
Wireless module for connecting to MultiLine® 3310/3510/36x0 IDS, inoLab® Multi IDS and MonoLine. Connects up to three sensors at the same time (depends on meter capabilities). Also for operation of OxiTop®-IDS.
From CHF 274.40*

Xylem Analytics Germany (WTW)
Multi parameter measuring instruments Multi 3620/3630 IDS SET WL for BSB measuring system OxiTop® IDS
Professional, digital multi-parameter measuring instument for mobile measurement, with 2 or 3 universal measuring channels, radio-ready, color graphic display, data logger and USB interfaces. Also for controlling OxiTop® IDS.Scope of supply: Instrument, short manual, CD-ROM, rechargeable batteries, driver software for USB, cable, power supply, protection SM Pro, IDS WLM-M module
From CHF 2,737.50*

Xylem Analytics Germany (WTW)
Stirring platforms OxiTop® for BOD measurement
These Stirring platforms have been specially developed for BOD measurement with the OxiTop® system. Software-controlled speed regulation prevents the magnetic stirrer bar from getting caught or wobbling. The speed is selected so that an optimal gas exchange with the sample takes place. The stirrer is maintenance-free and non-wearing as it contains no moving parts.The IS 6-Var model has been specially developed for use with large measuring vessels and has space for 6 measuring vessels. Its outer dimensions are identical to those of the IS 12.SpecificationsNumber of stirring positions:6 or 12Speed:180 to 450 rpm.Safety class:3, IEC 1010IP code:IP 30Power supply:100 ... 240 V, 50/60 Hz
From CHF 1,017.60*

Xylem Analytics Germany (WTW)
Adapter AD/SK for BOD measuring system OxiTop®
For OxiTop® measuring heads, for all sample and measuring bottles series PF45/.. and MF45/.., autoclavable (121 °C). Incl. OxiTop® AD adapter, OxiTop® SK screwable adapter, DI45 gasket for adapter VS45.
From CHF 140.30*

Similar products

Dissolved oxygen bottles, Winkler pattern
Winkler pattern. Soda-lime glass.For determination of dissolved oxygen in water. The measured capacity is specified to ± 0,01ml. With white labelling area. Solid, bevelled glass stopper, secured with an accessory spring clip. Each bottle is adjusted to the relevant stopper. Stoppers and bottles are therefore not interchangeable. Each bottle and its stopper is marked with a unique, matching identification number.
From CHF 33.90*

Xylem Analytics Germany (WTW)
Sample bottles for BOD measurement system OxiTop®
From CHF 30.30*

Thermostatic cabinets
The incubators from Lovibond® are designed for continuous tempering for different applications, mainly for the determination of BOD, the storage of wastewater samples, and the determination of enzymatic activity. The temperature range is +2°C up to +40°C and can be regulated in steps of 0,1°C. Temperature tolerance is defined with +/- 1°C respectively +/- 0,5°C (at 20°C). Low engergy consumption due to reinforced isolation. The interior of the cabinets is equipped with sockets for connecting stirrers. Illuminated LED display with actual / setpoint display.Temperature range 2 °C to 40 °C, continuously adjustable in steps of 0.1 °CLow power consumptionIlluminated LED display of preset and current temperaturesIdeal for BOD determination at 20 °CPower sockets inside the incubatorStandard door or glass doorSpecificationsCoolant:R134aFan:Axial, delivery rate 320m3/hPower supply:220-230V/50Hz* With glass door
From CHF 2,035.00*

Overflow Measuring Flask for OxiTop®
Glass measuring flask with fixed volume doses for the easy and accurate measurement of the required sample volume for respirometric BSB measurements.
From CHF 66.20*

Measuring heads OxiTop®-i
Menu-operated measuring heads. Output of the BOD measurement values directly on the display.3 operating buttonsBacklit graphic LCDControl LEDVolume pre-selectionMeasurement duration selectable (1 to 7 days)Display of measuring curveDisplay of current readings
From CHF 700.20*

RESPIROMETRIC Sensor System 6 BOD
Measuring systems for the reliable determination of 90 to 4000 ppm BOD, BOD5 and BOD7 for the control of water and wastewater quality.Complete with sensor heads and multi-position magnetic stirring station for performing aerobic and anaerobic respiration tests. Measurement data is transmitted wirelessly from the RESPIROMETRIC sensor head to a PC via the Databox™. The Databox™ can store results from up to 48 RESPIROMETRIC sensors. With the RESPIROSoft™ software, these measurement data can be evaluated and monitored on the PC. Alternatively, the Databox™ can be connected to the Velp Ermes cloud platform. After registration, measurement data can also be monitored and analysed from mobile devices.4-digit LED display2-button user interfaceResults available in BOD (mg/l) and pressure (mbar)Automatic conversion of pressure results into BODWireless transmission of data to the PC (Wlan)Scope of supply: 6-position magnetic stirring station, 6 x sensor heads incl. batteries, 6 x 500 ml amber bottles, 6 x KOH containers, 6 x magnetic stirring barsBOD range:90 ... 4000 ppmPressure range:500 ... 2000 mbarMeasuring period:5 ... 30 daysDimensions sensor (W x D x H):50 x 70 x 70 mmDimensions stirring station (W x D x H):270 x 185 x 300 mmWeight sensor:80 gWeight stirring station:1 kgPower supply sensor:2 x CR 2430Power supply stirring station:230 V, 50 ... 60 HzIP code:IP54
From CHF 3,964.05*

RESPIROMETRIC Sensor System 6, plastic biodegradability
Measuring systems for the reliable determination of the degree of biodegradability of plastic materials in an aqueous medium.Complete with sensor heads and multi-position magnetic stirrer for performing aerobic respiration tests. Measurement data is transmitted wirelessly from the RESPIROMETRIC sensor head to a PC via the Databox™. The Databox™ can store results from up to 48 RESPIROMETRIC sensors. With the RESPIROSoft™ software, these measurement data can be evaluated and monitored on the PC. Alternatively, the Databox™ can be connected to the Velp Ermes cloud platform. After registration, measurement data can also be monitored and analysed from mobile devices.4-digit LED display2-button user interfaceResults available in pressure (mbar)Magnetic stirrer with timer and electronic speed controlWireless transmission of data to the PC (Wlan)Scope of supply: 6-position magnetic stirrer MULTISTIRRER Digital, 6 x sensor heads incl. batteries, 6 x 1000 ml bottles, 6 x kits for plastic biodegradability analysis, 6 x magnetic stirring barsPressure range:500 ... 2000 mbarMeasuring period:1 ... 180 daysDimensions sensor (W x D x H):50 x 70 x 70 mmDimensions magnetic stirrer (W x D x H):230 x 370 x 51.5 mmWeight sensor:80 gWeight magnetic stirrer:1.75 kgPower supply sensor:2 x CR2430Power supply magnetic stirrer:100 ... 240 V, 50 ... 60 HzIP code:IP54Speed range magnetic stirrer:80 ... 1500 rpmStirring position distance magentic stirrer:100 mm
From CHF 5,163.57*

BOD-Measurement-System BD 600
BOD measurement is an important measurement of the effects of domestic and industrial waste water on sewage plants and outflow points. The sensor system BD 600 is a 6 sample system that allows precise measurements of BOD based on the manometric principle. Manometric respirometers relate oxygen uptake to the change in pressure caused by oxygen consumption while maintaining a constant volume. Due to the modern integral pressure sensors, it is not necessary to use mercury for the measurements. The BOD values are stored automatically in the sensor memory at regular intervals and can be called up on the large-format display at any time without the need for time-consuming conversion using factors. This means that test series that end on a Sunday can be evaluated during the following week without any problem. Measurement series can be stored on USB stick/ SD card or transferred via USB cable to evaluate the data on a computer. The measurement period is user-selectable between 1 and 28 days to suit the application. While short measurement periods are useful for scientific applications, standard BOD measurements typically extend over a period of 5 days - and manometric determination of OECD, for example, generally takes place over a period of 28 days.Scope of supply:BD 600, complete unit with 6 or 12* sensor heads and control unit with batteriesPower supply unit incl. Y-cable for common power supply of BD 600 and stirring unitInductive stirring unit6 or 12* sample bottles6 or 12* rubber gaskets6 or 12* magnetic stirring rods1 overflow flask, 157 ml1 overflow flask, 428 ml1 bottle, 50 ml potassium hydroxide solution1 bottle, 50 ml nitrification inhibitor solution1 instruction manualremote controlSpecificationsMeasuring principle:respirometric, electronic pressure sensorRanges:0 - 40, 0 - 80, 0 - 200, 0 - 400, 0 - 800, 0 - 2000, 0 - 4000 mg/l O2Measurement period:User-selectable, between 1 and 28 daysPower supply:100-240 V, battery buffered or via power supply using Y-cableProtection class:IP 54 (sensor head)Interface:USB host port (USB stick), USB device port (computer), SD cardClock:Real timeApplication:BOD5 / BODF / OECD301F* 6 or 12 depending on BOD-System (BD600 or BD606)
Price on request